Product Carousel Tabs
Abacus 5 Heamatology Analyzer (5 Part Diff)
Throughput: 60 tests/hour
Parameters: a CBC+5 DIFF mode (26 parameters) – 2
histograms: RBC, PLT; 2 scattergrams: 4 diff, WBC, LYM, MON, NEU, EOS, BAS, LYM%, MON%, NEU%, EOS%, BAS%, RBC, HCT, MCV, RDW (sd/cv), HGB, MCH, MCHC,PLT, PCT, MPV, PDW (sd/cv), P-LCC, P-LCR
Laser light: scattering technology for 5-part WBC
differential
Sample volume: 110 μl of whole blood
Closed and open tube sampling, optional autosampler
3 cyanide-free reagents: Diluent, Lyse, Stopper
Data storage capacity: 100,000 records
Operating environment: Temperature: 15–30 °C
Relative humidity: Max 80% (non-condensing)
Multilingual user interface: English, French, Spanish, Croatian, Hungarian,
Italian, Polish, Portuguese, Russian, Turkish, Chinese, German, Greek
Size (Width x Depth x Height): 40 cm x 50 cm x 45 cm, 16” x 20” x 18”
Weight: 35 kg, 77 lbs
Abacus 380 Haematology Analyzer
Abacus Junior Vet 5
eCL8000 eCLIA System
Throughput: 86 T/H
Methodology: Electro-chemluminescence Immunoassay (ECLIA)
Test Mode: Standard, STAT
Reagent Channel: 10
Sample Position: 30
Sample Type: Serum, Plasma
Sample Volume: 5-100µl
Reaction Position: 100
Reaction Cups: Disposable
Incubation Temperature: 37+0.50C
Sample Result: 10mins
Calibration: Auto and QC (2 level)
Reagent System: Liquid Level Detection; Refrigeration, 4-150C;
System Reagent: Buffer and Auffer; Slot Temperature 28+20C
Probe: Liquid Level Detection, Probe Crashing Protection, Probe
Blocking Detection
Optional Function: Automatic cap removing
Dimensions: 650mmx620mmx650mm (26.6”Hx24.4” Wx25.5”D)
Weight: 92Kg (203lbs)
Chemwell Fusion
Samples: Removable rack holds 96 serum vials or 12x75mm tubes, pre-
dilution on-board
Reagents: The standard rack holds 27 various size bottles, optional alternate
racks available
Reaction Plate: Standard 96-well microplates or strip trays – clear for ELISA and opaque white for Chemiluminescent
Linear Range: 0.0 to 3.0A
Filters: long-life IAD
Wavelengths: 340,405,450,505,545,600,630,700 or custom
Sensitivity/Detection Limit: ALP 1×10-21 moles
HRP 1×10-18 moles
Linear range: to 106 RLU
Cross talk: Less than 2.5 x 10-4
Volumes: from 2uL to 1.95 mL with precision better than 2%CV, single and
multi dispense
Probe: detects liquid surface, automatic washing and rinsing
Chemwell 2910 Fully Automated Elisa System
• 200 tests per hour
• No carry-over
• Liquid sensing probe tip
• 8-well wash head
• Level-sensing wash, rinse, and waste bottles
• LIS, STAT
• QC tracking
• Self-monitoring mechanics and optics
• Auto dilute and retest for over-range samples
• Reaction Volume <250uL
• No custom disposables required
• IAD filters
• Creates automatic service reports
• Edit standard curves
Typical throughput: Up to 200 endpoint reactions per hour, up to 170 kinetic
reactions per hour
Dimensions: 36.25″ (92.1cm) left to right, 18.75″ (47.6 cm) height, 21.5″ (54.6 cm) front-to-back
Approximate weight 100 lbs (45kg)
Capabilities: Dilution, pre-dilution, dispensing single or multiple reagents
Probes: 316 stainless steel for maximum reagent compatibility, level sensing
Maximum number of specimens: 96
Maximum number of reagents: Typically 27 to 44 or more (you can program reagents to go in the sample rack; assorted replaceable racks and custom-designed racks are available for various bottle sizes)
Standard reagent rack: 27
Reaction Vessel: Standard microwells, strips or plates
Products Carousel
Heamatology & Chemistry Analyzer
Reagents & Consumables
Trending Products
Bestsellers
Top Categories
Recommendation for you
Your Recently Viewed Products
Abacus Junior Vet 5
Gynocular Colposcope Gynius
Features
• Gold standard cervical examination rating
• CE marked and US FDA approved
• Red-free/green filter mode
• Replaceable/Rechargeable battery
• Hand held or used with a tripod
• Universal smartphone adapter for digital imaging
• Low cost halogen bulb
Focal Length (mm): 300
Weight (g): 480
Magnification (x): 5x 8x 12x
Field of View (mm): 40 30 20
Resolution (lines/mm): 25 40 60
Monmouth Guardian MSCEP 1200 Class II Microbiological Safety Cabinet
Monmouth Guardian MSCEP 1200 Class II Microbiological Safety Cabinet
External Dimensions: 1200mm (w) x 750mm (d) x 1330mm (h)
(2230mm including base stand)
Add 66mm height for outlet filter if fitted
Internal Dimensions: 1107mm (w) x 630mm (d) x 754mm (h)
Base Stand: Optional
Main HEPA Filter: H14 rated at 99.997% efficient to 0.3μm
particulate. Filter seals under negative pressure to prevent leaks into the cabinet.
Outlet HEPA Filter: H14 rated at 99.997% efficient to 0.3μm
particulate. Filter seals under negative pressure to prevent leaks into the cabinet.
Optional 2nd outlet filter available
Air Cleanliness: ISO Class 4
Low Overall Design: Yes
Sliding Sash Yes – Manufactured from Toughened and
Laminated Glass
Internal Lighting: High-intensity adjustable overhead LED lighting
UV Light: Yes – with timer
Electrical Requirements: 220-240V / 50-60Hz AC – 150w (during
Standard operation) 110V / 60Hz also available
Noise Level: circa. 54db(A)
Electrical Socket: 2 electric outlets switched from the main
control system
Net Weight: 170Kg
Construction: Epoxy coated Zintec Mild Steel with
toughened glass glazing panels and removable 3-part stainless steel work surface
eCL8000 eCLIA System
Throughput: 86 T/H
Methodology: Electro-chemluminescence Immunoassay (ECLIA)
Test Mode: Standard, STAT
Reagent Channel: 10
Sample Position: 30
Sample Type: Serum, Plasma
Sample Volume: 5-100µl
Reaction Position: 100
Reaction Cups: Disposable
Incubation Temperature: 37+0.50C
Sample Result: 10mins
Calibration: Auto and QC (2 level)
Reagent System: Liquid Level Detection; Refrigeration, 4-150C;
System Reagent: Buffer and Auffer; Slot Temperature 28+20C
Probe: Liquid Level Detection, Probe Crashing Protection, Probe
Blocking Detection
Optional Function: Automatic cap removing
Dimensions: 650mmx620mmx650mm (26.6”Hx24.4” Wx25.5”D)
Weight: 92Kg (203lbs)
Blood Roller Mixer
TECHNICAL SPECIFICATION:
Vibrating: 10-80rpm/min
Rolling: 10-80rpm/min
Vibrating Range: 22mm +/- 1mm
Power Consumption: 12w
Voltage: AC220V±10% (50/60Hz)
Net Weight: 3.6kg
Volume: 394x266x98
Fuse: 2A
Working Shift: continuously
Packing Quantity: 2 sets/package
Packing Measurement: 49*36*42
PRECAUTIONS
Put the machine on a flat table.
Machine should have a good earth.
ERBA XL-200 Fully Automated Chemistry Analyzer with ISE
Throughput: 200 photometric tests per hour and 400 tests per hour with ISE* (Optional ISE with Na, K+, Cl-, Li+)
System Type: Discrete, Open Automated, Random Access, Patient Prioritized Clinical Chemistry Analyzer
Onboard Parameters: upto 50 + 4 ISE
Sample Type: Serum, Plasma, Urine, CSF, HbA1c using Whole Blood
Programmable Parameters: Unlimited
Analytical Methods: 1-Point, 2-Point, Rate-A, Rate-B, Direct Potentiometry
Calibration: Linear, Non-Linear, Multipoint
Photometer: Static Photometer
Absorbance Range: 0-3.0 Absorbance
Light Source: Halogen Lamp 12V/20 W
Optics: 8 Filters (340-700nm) 340, 405, 505,546,578,600,660,700nm
Director: B Silicon photo diodes
Sample Unit: 39 positions for samples/blank/calibrator/control & STAT sample.
Chemwell 2910 Fully Automated Elisa System
• 200 tests per hour
• No carry-over
• Liquid sensing probe tip
• 8-well wash head
• Level-sensing wash, rinse, and waste bottles
• LIS, STAT
• QC tracking
• Self-monitoring mechanics and optics
• Auto dilute and retest for over-range samples
• Reaction Volume <250uL
• No custom disposables required
• IAD filters
• Creates automatic service reports
• Edit standard curves
Typical throughput: Up to 200 endpoint reactions per hour, up to 170 kinetic
reactions per hour
Dimensions: 36.25″ (92.1cm) left to right, 18.75″ (47.6 cm) height, 21.5″ (54.6 cm) front-to-back
Approximate weight 100 lbs (45kg)
Capabilities: Dilution, pre-dilution, dispensing single or multiple reagents
Probes: 316 stainless steel for maximum reagent compatibility, level sensing
Maximum number of specimens: 96
Maximum number of reagents: Typically 27 to 44 or more (you can program reagents to go in the sample rack; assorted replaceable racks and custom-designed racks are available for various bottle sizes)
Standard reagent rack: 27
Reaction Vessel: Standard microwells, strips or plates
Manual Vacuum Aspirator
Sterile
Available in 8 sizes
Two opposing apertures (4-8mm)
Large, single scoop aperture (9,10,12mm)
Color-coded by size for easy differentiation and identification (adapter kit required for the flexible Karman Cannula)
Printed insertion guides
Used for uterine aspiration in conjunction with the IPAS MVA Plus Aspirator and the Double Valve Aspirator (adapter kit required for the Flexible Karman Cannula) Sizes 4mm, 5mm and 6mm of the flexible Karman Cannula can also be used for uterine aspiration with the single valve aspiration. No adapters are required.
Semi-rigid: The tactile response of a rigid curette with the gentle probe of a flexible cannula
Utilizes permanently-integrated bases
Eliminates the need for adapters to connect to the aspirator
Constructed with “wings” to facilitate easy insertion and removal from the aspirator
Length: Approx. 24cm or 9.5in
Made of medical grade, latex free, polypropylene plastic.
Autoclave YX-280A
Features
High quality SUS304 stainless steel with 0 Cr18Ni9Ti
Overpressure auto-discharging at 0.145-0.165Mpa
The highest working temperature: 126°C-129°C, accuracy 1°C
Dual scale numerical pressure gage indicate temperature and pressure
Working pressure: 0.14-0.16Mpa
Electric heating system
Timer range: 0-80min
Silicone seal
Butterfly-nuts keep safe.
Technical Specification
Volume: 18L
Sterilizing Chamber Volume: Ø280*H243mm
Working Pressure: 0.145-0.165 0.145-0.165Mpa
Working Temperature: 1260C-1290C
Power: 220V, 50 HZ, 2KW
Timer: 0-80 minutes
Sterilizing Baskets: 1Pcs
Product Dimension: 38*38*51cm
Package Dimension: 40*40*53cm
Gross Weight/Net Weight: 17kg/16kg
Statfax 4500
PHOTOMETRIC:
Linear Measurement Range: Tube or cuvette -0.0 to 3.0 Absorbance units (A).
Photometric Accuracy: +/-(1% of the reading + 0.005A)
Stability: Drift of no more than 0.005A in 8 hours/bi-chromatic.
Light Source: Tungsten lamp with lamp saver feature
Standard Wavelengths: 340, 405, 505,545, 580 and 630nm (alternate filters available from 340 to 700nm)
Filter Type: IAD hardcoat interference, 10nm half bandpass
Tube Size: 12 mm round is standard.
Minimum Sample Volume: 1mL for 12mm round tube.