SPECIFICATION FOR DCEG MACHINE ELECTROCARDIOGRAPH
Number of Channels: 12 Channels
Machine Type : Digital
Lead Selection: Automatic
Frequency : 50Hz
Number of Channels: 12 Channels
Machine Type : Digital
Lead Selection: Automatic
Frequency : 50Hz
SPECIFICATION FOR DCEG MACHINE ELECTROCARDIOGRAPH
Number of Channels: 12 Channels
Machine Type : Digital
Lead Selection: Automatic
Frequency : 50Hz
SPECIFICATION FOR DCEG MACHINE ELECTROCARDIOGRAPH
Number of Channels: 12 Channels
Machine Type : Digital
Lead Selection: Automatic
Frequency : 50Hz
TECHNICAL SPECIFICATION FOR INCUBATOR (DNP-9052A)
Model: DNP-9052A
Working size (mm): 350x350x410
Power: 250W
Temperature range: Room temperature+5~65℃
Temperature resolution: 0.1℃
Temperature fluctuation: ±0.5℃
Timer: 0-999min
Voltage: 110V 60Hz /220V 50Hz
Dimension(mm): 470x490x700
Size : 58cm*56cm*80cm / 23in*22.1in*31.5in
Gross Weight : 45kg / 100lb
Net Weight : 34kg / 75lb
SPECIFICATION
Measure unit: 5/30 mg/dl or 85/510 µmol/l
Measure System: Photometric
Sample Reading: On a single-point of the capillary
Zero and checkings: Completely automated
Interferential: Automatically compensated
Reading Time: 3s approx. even on highly haemolized samples
Reading inaccuracy: <5%
Detector: Silicon photodiode
Optical Filters: 455 and 575nm
Programming: By membrane keypad
Results: On LCD and printer
Keypad: 17 buttons
Display: 2 lines with 16 columns
Printer: 20 columns with thermal paper
Data Storage: Last 100 results
Interface: SB Port
Complimentary Items
ACL-LP-0500 - Lancettes
ACL-PL-747500 - Sealing Plasticine
ACL-CP-74931 - Glass Capillaries (75mm)
CRT-01-058 - Thermal Paper
Clean, progressive design
• 15-inch high LED resolution monitor and optimum viewing
• 8.4 inch excellent sensitivity touch screen
• Four activated transducer connections
• Standard configured gel heating cup
• PW spectrum with auto measurement and analysis
• Carotid IMT auto measurement
• Unique puncture guide technology
• Intelligent navigation technology
• Support 3D/4D imaging
• Dual/triplex synchronous technology
• Preposed USB port hidden draw out keyboard
• DICOM 3.0 supported
• Support multiple data transmission interface.
Sample material: Capillary, venous or arterial whole blood.
Measurement range: 0-25.6 g/dL (0-256 g/L or 0-15.9 mmol/L).
Results: In about 10 seconds.
Sample volume: 10 µL.
Weight: 500 g (1.10 pounds) with batteries installed.
Power: AC adapter or batteries.
Operating temperature: 10-40 °C (40-104 °F).
Interface: Printer and PC
Quality control: Built-in “selftest”. The system can be verified using liquid controls.
Calibration: The system is factory calibrated against the ICSH reference method for hemoglobin and needs no further calibration.
Accuracy: Correlation of 0.99 when compared to the reference method (ICSH
method).