Chemistry Analyzer
Showing all 8 results
-
Chemistry Analyzers, Medical Equipments
Chem 5V3 Chemistry Analyzer
Unique Features of Chem 5V3:
• 150 Open Programmable Test Memory
• 10 Assay Modes including Absorbance, Linear & Non-Linear Calculations for 1 Point, Rate A & 1 Point sample blank methods
• Dual Cuvette Facility
• Low Volume Flowcell for low reagent/Test
• Extensive Q.C. Program and Memory facility
• Universal Power Adaptor for ease of usNo of Test Parameters: 150, Open user programmable
Assay Modes: 10
Measurement Modes: Monochromatic/Bi-chromatic
Flowcell Temperature: 25” C, 30o C, 37o C, by Peltier control
Type of Cuvettes: Dual Cuvette (Flow cell and Polystyrene manual cuvette)
Flow cell volume: 18 ul/33ul (optional)
Aspiration volume: 300-999 ul (user programmable) using peristaltic pump
Wavelengths: 340,405,505,546,578,630nm
Display: 240 x 64 Graphic LCD display
Printer: External and Internal
Interface port: RS 232 c Serial interface & Centronics parallel port for external printer.SKU: n/a -
Chemistry Analyzers, Medical Equipments, Other Instruments
Chemwell 2902 Fully Automated Chemistry Analyzer
Chemistry Analyzers, Medical Equipments, Other InstrumentsChemwell 2902 Fully Automated Chemistry Analyzer
• 200 tests per hour
• No carry-over
• Liquid sensing probe tip
• Reflex testing
• Continuous loading
• LIS, STAT
• QC tracking
• Self-monitoring mechanics and optics
• Auto dilute and retest for over-range samples
• Reaction Volume <250uL
• No custom disposables required
• IAD filters
• Automatic service reports
• Standard curve editingSKU: n/a -
Chemistry Analyzers, Medical Equipments
Chemwell 2910 Fully Automated Elisa System
• 200 tests per hour
• No carry-over
• Liquid sensing probe tip
• 8-well wash head
• Level-sensing wash, rinse, and waste bottles
• LIS, STAT
• QC tracking
• Self-monitoring mechanics and optics
• Auto dilute and retest for over-range samples
• Reaction Volume <250uL
• No custom disposables required
• IAD filters
• Creates automatic service reports
• Edit standard curvesTypical throughput: Up to 200 endpoint reactions per hour, up to 170 kinetic
reactions per hour
Dimensions: 36.25″ (92.1cm) left to right, 18.75″ (47.6 cm) height, 21.5″ (54.6 cm) front-to-back
Approximate weight 100 lbs (45kg)
Capabilities: Dilution, pre-dilution, dispensing single or multiple reagents
Probes: 316 stainless steel for maximum reagent compatibility, level sensingMaximum number of specimens: 96
Maximum number of reagents: Typically 27 to 44 or more (you can program reagents to go in the sample rack; assorted replaceable racks and custom-designed racks are available for various bottle sizes)
Standard reagent rack: 27
Reaction Vessel: Standard microwells, strips or platesSKU: n/a -
Chemistry Analyzers, Medical Equipments, Other Instruments
Chemwell Fusion
Samples: Removable rack holds 96 serum vials or 12x75mm tubes, pre-
dilution on-board
Reagents: The standard rack holds 27 various size bottles, optional alternate
racks available
Reaction Plate: Standard 96-well microplates or strip trays – clear for ELISA and opaque white for Chemiluminescent
Linear Range: 0.0 to 3.0A
Filters: long-life IAD
Wavelengths: 340,405,450,505,545,600,630,700 or custom
Sensitivity/Detection Limit: ALP 1×10-21 moles
HRP 1×10-18 moles
Linear range: to 106 RLU
Cross talk: Less than 2.5 x 10-4
Volumes: from 2uL to 1.95 mL with precision better than 2%CV, single and
multi dispense
Probe: detects liquid surface, automatic washing and rinsingSKU: n/a -
Chemistry Analyzers, Medical Equipments
Chemwell T Fully Automated Chemistry Analyzer
Typical throughput : 32 test per 3 hour assay procedure including calibrators and controls
Total reagent volume Initial: 255 µl
per sample: R1, R2, R3: 65µl each
Final reagent: 60µl
Extraction: 300µl
Reading: 200µl
General Reagent and Sample Handling
Functions: Dilution, pre-dilution, dispensing samples and reagents
Syringe Pump: Capacity 500µl, range 2µl – 450µl. Settings in increments of 0.5µl
Probe: 316L stainless steel for maximum reagent compatibility, level sensingSKU: n/a -
Chemistry Analyzers, Medical Equipments, Other Instruments
eCL8000 eCLIA System
Throughput: 86 T/H
Methodology: Electro-chemluminescence Immunoassay (ECLIA)
Test Mode: Standard, STAT
Reagent Channel: 10
Sample Position: 30
Sample Type: Serum, Plasma
Sample Volume: 5-100µl
Reaction Position: 100
Reaction Cups: Disposable
Incubation Temperature: 37+0.50C
Sample Result: 10mins
Calibration: Auto and QC (2 level)
Reagent System: Liquid Level Detection; Refrigeration, 4-150C;
System Reagent: Buffer and Auffer; Slot Temperature 28+20C
Probe: Liquid Level Detection, Probe Crashing Protection, Probe
Blocking Detection
Optional Function: Automatic cap removing
Dimensions: 650mmx620mmx650mm (26.6”Hx24.4” Wx25.5”D)
Weight: 92Kg (203lbs)SKU: n/a -
Chemistry Analyzers, Medical Equipments, Other Instruments
Statfax 3300 Chemistry Analyzer
• Uses 12 mm round tubes, 1 cm square cuvettes, or built-in flow cell.
• Read cell is temperature-controlled to 37°C.
• Bi-chromatic reading capability 6 filters standard, with spaces for 2 optional filters (340-
o 700nm).
• Flip-up 240 x 128-pixel graphic display shows kinetic plots in real-time.
• Use onboard thermal printer, external printer, or PC.
• Create a work list, run tests, print patient reports. Stores patient data
• Stores control values and creates Levey-Jennings plots for QC.
• IAD filters
• OPTIONAL ACCESSORIES FOR STAT FAX 3300
• Incubates 18 Tubes at 37°C.
• LED at front indicates heating function.
• Temperature displays on 3300 screen.
Tube or cuvette: -0.2 to 2.5 absorbance units
With Flowcell: -0.2 to 3.5 absorbance units
Stability: Drift of no more than 0.005A in 8 hours/bi-
chromaticSKU: n/a -
Chemistry Analyzers, Medical Equipments
Statfax 4500
PHOTOMETRIC:
Linear Measurement Range: Tube or cuvette -0.0 to 3.0 Absorbance units (A).
Photometric Accuracy: +/-(1% of the reading + 0.005A)
Stability: Drift of no more than 0.005A in 8 hours/bi-chromatic.
Light Source: Tungsten lamp with lamp saver feature
Standard Wavelengths: 340, 405, 505,545, 580 and 630nm (alternate filters available from 340 to 700nm)
Filter Type: IAD hardcoat interference, 10nm half bandpass
Tube Size: 12 mm round is standard.
Minimum Sample Volume: 1mL for 12mm round tube.SKU: n/a