Chemwell 2910 Fully Automated Elisa System


• 200 tests per hour
• No carry-over
• Liquid sensing probe tip
• 8-well wash head
• Level-sensing wash, rinse, and waste bottles
• LIS, STAT
• QC tracking
• Self-monitoring mechanics and optics
• Auto dilute and retest for over-range samples
• Reaction Volume <250uL
• No custom disposables required
• IAD filters
• Creates automatic service reports
• Edit standard curves

Typical throughput: Up to 200 endpoint reactions per hour, up to 170 kinetic
reactions per hour
Dimensions: 36.25″ (92.1cm) left to right, 18.75″ (47.6 cm) height, 21.5″ (54.6 cm) front-to-back
Approximate weight 100 lbs (45kg)
Capabilities: Dilution, pre-dilution, dispensing single or multiple reagents
Probes: 316 stainless steel for maximum reagent compatibility, level sensing

Maximum number of specimens: 96
Maximum number of reagents: Typically 27 to 44 or more (you can program reagents to go in the sample rack; assorted replaceable racks and custom-designed racks are available for various bottle sizes)
Standard reagent rack: 27
Reaction Vessel: Standard microwells, strips or plates

FEATURES:
Chemwell 2910 is a completely open system that is easy to program. Set up assays, routine jobs, quality control, panels, and even index calculations to suit your laboratory. With a completely open system you can program additional wash volume, increase the number of washes, or even direct the probe to pick up and dispense a probe cleaning solution after each specimen. And it is entirely password protected.

Precise pipetting of low volume specimens, elimination of carryover, and careful control of temperature are all essential for reliable results. Chemwell 2910 EIA can make pre-dilutions.

However, this is rarely necessary since a high level of precision is achieved even with a 2uL sample. Chemwell 2910 can process EIA at ambient temperature or 37°C. An incubator is provided for biochemistry wells to provide precise kinetic reactions. The probe is also temperature controlled to deliver 37°C reagents.
• 200 tests per hour
• No carry-over
• Liquid sensing probe tip
• 8-well wash head
• Level-sensing wash, rinse, and waste bottles
• LIS, STAT
• QC tracking
• Self-monitoring mechanics and optics
• Auto dilute and retest for over-range samples
• Reaction Volume <250uL
• No custom disposables required
• IAD filters
• Creates automatic service reports
• Edit standard curves

Typical throughput: Up to 200 endpoint reactions per hour, up to 170 kinetic
reactions per hour
Dimensions: 36.25″ (92.1cm) left to right, 18.75″ (47.6 cm) height, 21.5″ (54.6 cm) front-to-back
Approximate weight 100 lbs (45kg)
Capabilities: Dilution, pre-dilution, dispensing single or multiple reagents
Probes: 316 stainless steel for maximum reagent compatibility, level sensing

Maximum number of specimens: 96
Maximum number of reagents: Typically 27 to 44 or more (you can program reagents to go in the sample rack; assorted replaceable racks and custom designed racks are available for various bottle sizes)
Standard reagent rack: 27
Reaction Vessel: Standard micro wells, strips or plates

Instrument bottles: 2L wash with low volume warning sensor, 1L rinse (or second wash) with low volume warning sensor,
2L waste bottle with full sensor. 1L priming bottle
EIA Mode: Incubation timing is software controlled; set each row of 8 to time separately
or time the whole plate together.
Thermal control: Well, probe, and tubing; ambient or 37C (other options also available)
Reagant cooling: RCA, Reagent Cooling Accessory optional) cools 12 to 15C below ambient through peltier
thermoelectric modules connected to an external controller
Wash head: 8-probe, automatic prime and rinse
Programs: Create and run user programmable protocols, aspirate, dispense, soak, mix…
Optical design: Reads absorbance in 4 simultaneous channels, NIST traceable calibration user
selected monochromatic or biochromatic results 8 position filter wheels:
340, 405, 450, 505, 545, 600, 630, 700 or custom
Interference filters: Long life, hard coat, ion assisted deposition, 10nm typical half bandpass
Linear Range: -0.2 to 3.0A
Photometer Accuracy: +/- 1% or better
Certifications: NRTL Listed, CE Marked