- Samples: Removable rack holds 96 serum vials or 12x75mm tubes, pre-
- dilution on-board
- Reagents: The standard rack holds 27 various size bottles, optional alternate
- racks available
- Reaction Plate: Standard 96-well microplates or strip trays – clear for ELISA and opaque white for Chemiluminescent
- Linear Range: 0.0 to 3.0A
- Filters: long-life IAD
- Wavelengths: 340,405,450,505,545,600,630,700 or custom
- Sensitivity/Detection Limit: ALP 1×10-21 moles
- HRP 1×10-18 moles
- Linear range: to 106 RLU
- Cross talk: Less than 2.5 x 10-4
- Volumes: from 2uL to 1.95 mL with precision better than 2%CV, single and
- multi dispense
- Probe: detects liquid surface, automatic washing and rinsing
- Strip Washer: 8-probe manifold, two wash buffers on board
- Dimensions: 86cm W x 51cm L x 40cm H, approx. weight = 35kg
- 34″ W x 20″ L x 16″ H, approx. weight = 77 lbs.
- Power: 100 – 250 VAC, 50-60 Hz
- USB port and cable supplied
- Single and multi-calibrator: Curve storage
- Linear and point-to-point: Curve editing
- Linear and non-regressions: Levy-Jennings plots
- Log-logit, cubic spline: Cutoff calculations
Chemistry Analyzers, Medical Equipments, Other Instruments
Chemwell Fusion
Samples: Removable rack holds 96 serum vials or 12x75mm tubes, pre-
dilution on-board
Reagents: The standard rack holds 27 various size bottles, optional alternate
racks available
Reaction Plate: Standard 96-well microplates or strip trays – clear for ELISA and opaque white for Chemiluminescent
Linear Range: 0.0 to 3.0A
Filters: long-life IAD
Wavelengths: 340,405,450,505,545,600,630,700 or custom
Sensitivity/Detection Limit: ALP 1×10-21 moles
HRP 1×10-18 moles
Linear range: to 106 RLU
Cross talk: Less than 2.5 x 10-4
Volumes: from 2uL to 1.95 mL with precision better than 2%CV, single and
multi dispense
Probe: detects liquid surface, automatic washing and rinsing
- Samples: Removable rack holds 96 serum vials or 12x75mm tubes, pre-
- dilution on-board
- Reagents: The standard rack holds 27 various size bottles, optional alternate
- racks available
- Reaction Plate: Standard 96-well microplates or strip trays – clear for ELISA and opaque white for Chemiluminescent
- Linear Range: 0.0 to 3.0A
- Filters: long-life IAD
- Wavelengths: 340,405,450,505,545,600,630,700 or custom
- Sensitivity/Detection Limit: ALP 1×10-21 moles
- HRP 1×10-18 moles
- Linear range: to 106 RLU
- Cross talk: Less than 2.5 x 10-4
- Volumes: from 2uL to 1.95 mL with precision better than 2%CV, single and
- multi dispense
- Probe: detects liquid surface, automatic washing and rinsing
- Strip Washer: 8-probe manifold, two wash buffers on board
- Dimensions: 86cm W x 51cm L x 40cm H, approx. weight = 35kg
- 34″ W x 20″ L x 16″ H, approx. weight = 77 lbs.
- Power: 100 – 250 VAC, 50-60 Hz
- USB port and cable supplied
- Single and multi-calibrator: Curve storage
- Linear and point-to-point: Curve editing
- Linear and non-regressions: Levy-Jennings plots
- Log-logit, cubic spline: Cutoff calculations