Statfax 3300 Chemistry Analyzer


• Uses 12 mm round tubes, 1 cm square cuvettes, or built-in flow cell.
• Read cell is temperature-controlled to 37°C.
• Bi-chromatic reading capability 6 filters standard, with spaces for 2 optional filters (340-
o 700nm).
• Flip-up 240 x 128-pixel graphic display shows kinetic plots in real-time.
• Use onboard thermal printer, external printer, or PC.
• Create a work list, run tests, print patient reports. Stores patient data
• Stores control values and creates Levey-Jennings plots for QC.
• IAD filters
• OPTIONAL ACCESSORIES FOR STAT FAX 3300
• Incubates 18 Tubes at 37°C.
• LED at front indicates heating function.
• Temperature displays on 3300 screen.
Tube or cuvette: -0.2 to 2.5 absorbance units
With Flowcell: -0.2 to 3.5 absorbance units
Stability: Drift of no more than 0.005A in 8 hours/bi-
chromatic

• Uses 12 mm round tubes, 1 cm square cuvettes, or built-in flow cell.
• Read cell is temperature-controlled to 37°C.
• Bi-chromatic reading capability 6 filters standard, with spaces for 2 optional filters (340-
o 700nm).
• Flip-up 240 x 128-pixel graphic display shows kinetic plots in real-time.
• Use on-board thermal printer, external printer, or PC.
• Create a work list, run tests, print patient reports. Stores patient data
• Stores control values and creates Levey-Jennings plots for QC.
• IAD filters
• OPTIONAL ACCESSORIES FOR STAT FAX 3300
• Incubates 18 Tubes at 37°C.
• LED at front indicates heating function.
• Temperature displays on 3300 screen.
Tube or cuvette: -0.2 to 2.5 absorbance units
With Flowcell: -0.2 to 3.5 absorbance units
Stability: Drift of no more than 0.005A in 8 hours/bi-
chromatic
Light Source: Tungsten halogen lamp, with lamp saver feature
Standard wavelengths: 340,405,505,545,580, 630nm plus 2 optional
Filter types: Ultra long life multiple cavity IAD hard coat
Sample Volume – Flowcell: Programmable 250µL – 750µL
Flowcell Body: Surgical grade stainless steel
Windows: Pyrex
Illuminated Volume: 21µL
Minimum Volume – Tube (12mm): 1mL
Minimum Volume – Cuvette: 400µL
Processor: Z180
Program Memory: 1 megabit
Non-volatile Memory: 1 megabit
RAM: 32k byte
Internal Printer: 40/80 column thermal
Display: Graphical LCD 240 x 128
Keyboard: 20 key, domed membrane
PC keyboard: Compatible with standard PS2 keyboard
Output- RS232: 9600 8 data, 1 stop, no parity
Output-Parallel Any IBM printer with simple ASCII compatibility
Single and multipoint
standardization:
Rate (factor/standard) Live graphical display of reaction
Curve fit: Linear, point to point, or regression
Miscellaneous: Blank and curve recall, sample blanking
Enclosure: Fire retardant ABS and steel
16” (40cm) x 14.5” (37cm) x 5.5” (14cm)
Weight: (17 lbs) 6.4 kg
Power: 100-240 VAC (self-sensing) 50/60 HZ input; 90
Watts

• Uses 12 mm round tubes, 1 cm square cuvettes, or built-in flow cell.
• Read cell is temperature-controlled to 37°C.
• Bi-chromatic reading capability 6 filters standard, with spaces for 2 optional filters (340-
o 700nm).
• Flip-up 240 x 128-pixel graphic display shows kinetic plots in real-time.
• Use on-board thermal printer, external printer, or PC.
• Create a work list, run tests, print patient reports. Stores patient data
• Stores control values and creates Levey-Jennings plots for QC.
• IAD filters
• OPTIONAL ACCESSORIES FOR STAT FAX 3300
• Incubates 18 Tubes at 37°C.
• LED at front indicates heating function.
• Temperature displays on 3300 screen.
Tube or cuvette: -0.2 to 2.5 absorbance units
With Flowcell: -0.2 to 3.5 absorbance units
Stability: Drift of no more than 0.005A in 8 hours/bi-
chromatic
Light Source: Tungsten halogen lamp, with lamp saver feature
Standard wavelengths: 340,405,505,545,580, 630nm plus 2 optional
Filter types: Ultra long life multiple cavity IAD hard coat
Sample Volume – Flowcell: Programmable 250µL – 750µL
Flowcell Body: Surgical grade stainless steel
Windows: Pyrex
Illuminated Volume: 21µL
Minimum Volume – Tube (12mm): 1mL
Minimum Volume – Cuvette: 400µL
Processor: Z180
Program Memory: 1 megabit
Non-volatile Memory: 1 megabit
RAM: 32k byte
Internal Printer: 40/80 column thermal
Display: Graphical LCD 240 x 128
Keyboard: 20 key, domed membrane
PC keyboard: Compatible with standard PS2 keyboard
Output- RS232: 9600 8 data, 1 stop, no parity
Output-Parallel Any IBM printer with simple ASCII compatibility
Single and multipoint
standardization:
Rate (factor/standard) Live graphical display of reaction
Curve fit: Linear, point to point, or regression
Miscellaneous: Blank and curve recall, sample blanking
Enclosure: Fire retardant ABS and steel
16” (40cm) x 14.5” (37cm) x 5.5” (14cm)
Weight: (17 lbs) 6.4 kg
Power: 100-240 VAC (self-sensing) 50/60 HZ input; 90
Watts

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Statfax 3300 Chemistry Analyzer”

There are no reviews yet.