Product Carousel Tabs
Abacus 5 Heamatology Analyzer (5 Part Diff)
Throughput: 60 tests/hour
Parameters: a CBC+5 DIFF mode (26 parameters) – 2
histograms: RBC, PLT; 2 scattergrams: 4 diff, WBC, LYM, MON, NEU, EOS, BAS, LYM%, MON%, NEU%, EOS%, BAS%, RBC, HCT, MCV, RDW (sd/cv), HGB, MCH, MCHC,PLT, PCT, MPV, PDW (sd/cv), P-LCC, P-LCR
Laser light: scattering technology for 5-part WBC
differential
Sample volume: 110 μl of whole blood
Closed and open tube sampling, optional autosampler
3 cyanide-free reagents: Diluent, Lyse, Stopper
Data storage capacity: 100,000 records
Operating environment: Temperature: 15–30 °C
Relative humidity: Max 80% (non-condensing)
Multilingual user interface: English, French, Spanish, Croatian, Hungarian,
Italian, Polish, Portuguese, Russian, Turkish, Chinese, German, Greek
Size (Width x Depth x Height): 40 cm x 50 cm x 45 cm, 16” x 20” x 18”
Weight: 35 kg, 77 lbs
Abacus 380 Haematology Analyzer
Abacus Junior Vet 5
eCL8000 eCLIA System
Throughput: 86 T/H
Methodology: Electro-chemluminescence Immunoassay (ECLIA)
Test Mode: Standard, STAT
Reagent Channel: 10
Sample Position: 30
Sample Type: Serum, Plasma
Sample Volume: 5-100µl
Reaction Position: 100
Reaction Cups: Disposable
Incubation Temperature: 37+0.50C
Sample Result: 10mins
Calibration: Auto and QC (2 level)
Reagent System: Liquid Level Detection; Refrigeration, 4-150C;
System Reagent: Buffer and Auffer; Slot Temperature 28+20C
Probe: Liquid Level Detection, Probe Crashing Protection, Probe
Blocking Detection
Optional Function: Automatic cap removing
Dimensions: 650mmx620mmx650mm (26.6”Hx24.4” Wx25.5”D)
Weight: 92Kg (203lbs)
Chemwell Fusion
Samples: Removable rack holds 96 serum vials or 12x75mm tubes, pre-
dilution on-board
Reagents: The standard rack holds 27 various size bottles, optional alternate
racks available
Reaction Plate: Standard 96-well microplates or strip trays – clear for ELISA and opaque white for Chemiluminescent
Linear Range: 0.0 to 3.0A
Filters: long-life IAD
Wavelengths: 340,405,450,505,545,600,630,700 or custom
Sensitivity/Detection Limit: ALP 1×10-21 moles
HRP 1×10-18 moles
Linear range: to 106 RLU
Cross talk: Less than 2.5 x 10-4
Volumes: from 2uL to 1.95 mL with precision better than 2%CV, single and
multi dispense
Probe: detects liquid surface, automatic washing and rinsing
Chemwell 2910 Fully Automated Elisa System
• 200 tests per hour
• No carry-over
• Liquid sensing probe tip
• 8-well wash head
• Level-sensing wash, rinse, and waste bottles
• LIS, STAT
• QC tracking
• Self-monitoring mechanics and optics
• Auto dilute and retest for over-range samples
• Reaction Volume <250uL
• No custom disposables required
• IAD filters
• Creates automatic service reports
• Edit standard curves
Typical throughput: Up to 200 endpoint reactions per hour, up to 170 kinetic
reactions per hour
Dimensions: 36.25″ (92.1cm) left to right, 18.75″ (47.6 cm) height, 21.5″ (54.6 cm) front-to-back
Approximate weight 100 lbs (45kg)
Capabilities: Dilution, pre-dilution, dispensing single or multiple reagents
Probes: 316 stainless steel for maximum reagent compatibility, level sensing
Maximum number of specimens: 96
Maximum number of reagents: Typically 27 to 44 or more (you can program reagents to go in the sample rack; assorted replaceable racks and custom-designed racks are available for various bottle sizes)
Standard reagent rack: 27
Reaction Vessel: Standard microwells, strips or plates