Medical Equipments
Showing 25–47 of 47 results
-
Medical Equipments, Other Instruments
I8-M700 Medical Waste Incinerator
MEDICAL WASTE INCINERATOR I8-M700-1
Combustion Chamber Volume (m3): 6.75m3
Mental thickness: 4mm
Burn Rate: up to 300kg per hour
Oprational Temperature: >850°C
Gas Rention: 2 Secs
Fuel Consumption: 40 – 50 ltrs per hour
Average Ash Residue (%): 3%
Thermostatic Device: Yes
Shippin weight (Kg): 15000kg
Dimensions (l, w, h): 6.04m x 1.91m x 5.75m
Door Size(m): 4.58m x 1.50m
Parameter Limits Measured
Total dust 30 mg/m3 12 mg/m3
Sulphur dioxide 200 mg/m3 2,4 mg/m3
Nitrogen dioxide 400 mg/m3 60 mg/m3
Carbon monoxide 100 mg/m3 78,3 mg/mSKU: n/a -
Medical Equipments, Other Instruments
Incubator DNP-9052A
TECHNICAL SPECIFICATION FOR INCUBATOR (DNP-9052A)
Model: DNP-9052A
Working size (mm): 350x350x410
Power: 250W
Temperature range: Room temperature+5~65℃
Temperature resolution: 0.1℃
Temperature fluctuation: ±0.5℃
Timer: 0-999min
Voltage: 110V 60Hz /220V 50Hz
Dimension(mm): 470x490x700
Size : 58cm*56cm*80cm / 23in*22.1in*31.5in
Gross Weight : 45kg / 100lb
Net Weight : 34kg / 75lbSKU: n/a -
Maternal Health, Medical Equipments
Manual Vacuum Aspirator
Sterile
Available in 8 sizes
Two opposing apertures (4-8mm)
Large, single scoop aperture (9,10,12mm)
Color-coded by size for easy differentiation and identification (adapter kit required for the flexible Karman Cannula)
Printed insertion guides
Used for uterine aspiration in conjunction with the IPAS MVA Plus Aspirator and the Double Valve Aspirator (adapter kit required for the Flexible Karman Cannula) Sizes 4mm, 5mm and 6mm of the flexible Karman Cannula can also be used for uterine aspiration with the single valve aspiration. No adapters are required.
Semi-rigid: The tactile response of a rigid curette with the gentle probe of a flexible cannula
Utilizes permanently-integrated bases
Eliminates the need for adapters to connect to the aspirator
Constructed with “wings” to facilitate easy insertion and removal from the aspirator
Length: Approx. 24cm or 9.5in
Made of medical grade, latex free, polypropylene plastic.SKU: n/a -
ELISA Analyzer, Medical Equipments
Micro Plate Reader Stat Fax 4200
UNIQUE FEATURES
• User-programmable open system.
• User-programmable plate formatting.
• Fully automatic reading.
• Reads 96 wells in about 12 seconds.
• Built-in thermal printer with graphics capability.
• Interactive touch-screen LCD with USB mouse option.
• Bi-chromatic optics.
• Standard model includes four filters.
• Six-filter models are available.
• IAD filtersSPECIFICATIONS
PHOTOMETRIC
Linear Measurement Range: 0.0 to 4.0 Absorbance Units (A)
Photometric Accuracy: +/-1%
Stability: Drift of no more than 0.005A in 8 hours
Light Source: Remote halogen lamp source with lamp saver feature.
Wavelengths: Standard: 405, 450, 492, 545, 600, and 630nm
6-filter: 405, 450, 492, 545, 600, and 630nm
Filter options from 405nm to 700nm
Filter type: IAD hardcoat interference, 10nm half bandpass
Vessel: Standard 96-well micro-titer plates, or strip trays.
ELECTRONIC
Display: Interactive 5.7” (14.5cm) graphical touch-screen LCD
Printer: Thermal dot matrix, 20 character per line, plus graphics.
Power Requirements: 115V or 230V AC, 50-60Hz (auto-sensing)
Interface: USB mouse
Speed: Read absorbance of 96 wells in about 10 seconds.
Plate Transport: Stepper motorSKU: n/a -
Biosafety Cabinet, Other Instruments
Monmouth Guardian MSCEP 1200 Class II Microbiological Safety Cabinet
Biosafety Cabinet, Other InstrumentsMonmouth Guardian MSCEP 1200 Class II Microbiological Safety Cabinet
External Dimensions: 1200mm (w) x 750mm (d) x 1330mm (h)
(2230mm including base stand)
Add 66mm height for outlet filter if fitted
Internal Dimensions: 1107mm (w) x 630mm (d) x 754mm (h)
Base Stand: Optional
Main HEPA Filter: H14 rated at 99.997% efficient to 0.3μm
particulate. Filter seals under negative pressure to prevent leaks into the cabinet.
Outlet HEPA Filter: H14 rated at 99.997% efficient to 0.3μm
particulate. Filter seals under negative pressure to prevent leaks into the cabinet.
Optional 2nd outlet filter available
Air Cleanliness: ISO Class 4
Low Overall Design: Yes
Sliding Sash Yes – Manufactured from Toughened and
Laminated Glass
Internal Lighting: High-intensity adjustable overhead LED lighting
UV Light: Yes – with timer
Electrical Requirements: 220-240V / 50-60Hz AC – 150w (during
Standard operation) 110V / 60Hz also available
Noise Level: circa. 54db(A)
Electrical Socket: 2 electric outlets switched from the main
control system
Net Weight: 170Kg
Construction: Epoxy coated Zintec Mild Steel with
toughened glass glazing panels and removable 3-part stainless steel work surfaceSKU: n/a -
Medical Equipments, Other Instruments
Neo-Bil Plus
SPECIFICATION
Measure unit: 5/30 mg/dl or 85/510 µmol/l
Measure System: Photometric
Sample Reading: On a single-point of the capillary
Zero and checkings: Completely automated
Interferential: Automatically compensated
Reading Time: 3s approx. even on highly haemolized samples
Reading inaccuracy: <5% Detector: Silicon photodiode Optical Filters: 455 and 575nm Programming: By membrane keypad Results: On LCD and printer Keypad: 17 buttons Display: 2 lines with 16 columns Printer: 20 columns with thermal paper Data Storage: Last 100 results Interface: SB Port Complimentary Items ACL-LP-0500 - Lancettes ACL-PL-747500 - Sealing Plasticine ACL-CP-74931 - Glass Capillaries (75mm) CRT-01-058 - Thermal PaperSKU: n/a -
Medical Equipments, Other Instruments
Oven OV-9023A
Model: OV-9023A
Working size(mm): 300x300x275
Power: 500W
Temperature range: RT+10-200℃
Temperature resolution: 0.1℃
Temperature fluctuation: ±1℃
Timer: 0-999min
Voltage: 110V 60Hz / 220V 50Hz
Dimension(mm): 400x570x630
Size : 60cm*53cm*73cm / 23.7in*20.9in*28.8in
Gross Weight : 36kg / 80lb
Net Weight : 28kg/ 62lbSKU: n/a -
Medical Equipments, Other Instruments
Patient Monitor 7000D
• Original perfusion index(PI) and show signal quality of blood oxygen infusion.
• One key reset alarm preset values
• Arrhythmia analysis, ST segment analysis and drug concentration and titrationable calculation,
• ST base dot automatically adjustment
• Defibrillation and resistance electrome design
• Excellent workmanship and high quality accessories
• Powerful storage function: 2000 NIBP measured value, 200 Alarm events, 1000 hours trend chart
• review, 1000 hours trend table review, 120 minutes dynamic trend, 8 minutes SpO2 figures and 48
• hours holographic waveformSKU: n/a -
Electrophoresis, Medical Equipments
Picophor Electrophoresis & Microphor Scanner
Pichophor
Electrophoretic Power Supply
Electrophoretic Chamber
Multiple Work Support with Application Plate
Samples Plates at 40 Position for Serum Protein and Hemoglobins
Applicator for Serum proteins and Hemoglobins
Applicator for Immunofixation
Samples Plate at 5 positions for Immunfixation
Electrophoretic Power Supply
PicoPhor Electrophoretic Power supply unit can be programmes both in voltage and in current thanks to its multifunction selector, its display and its easy-to use menu system.
Immunofixation
Picophor offers all the simplicity and speed possible in preparing samples of proteins immunofixationSKU: n/a -
Medical Equipments, Other Instruments, Ultrasound
Q3 3D/4D Ultrasound Colour Doppler
Clean, progressive design
• 15-inch high LED resolution monitor and optimum viewing
• 8.4 inch excellent sensitivity touch screen
• Four activated transducer connections
• Standard configured gel heating cup
• PW spectrum with auto measurement and analysis
• Carotid IMT auto measurement
• Unique puncture guide technology
• Intelligent navigation technology
• Support 3D/4D imaging
• Dual/triplex synchronous technology
• Preposed USB port hidden draw out keyboard
• DICOM 3.0 supported
• Support multiple data transmission interface.SKU: n/a -
Maternal Health, Medical Equipments, Point of Care
Signos RT Ultrasound Machine (Point-of-Care)
• The fastest and easiest access to key obstetric applications
• Strong, durable and robust design
• Instant power on and long lasting battery
• Reduced procedural complications
• Early obstetric selection for first trimester scanning
• Direct connection to window based PC, laptop or tablet
• Instant insight at the point of care
• Aids ruling in obvious pathologySKU: n/a -
ELISA Analyzer, Medical Equipments
Statfax 2200
FEATURES:
• Compact and easy to operate.
• Holds two 96 well microplates for mixing and/or incubating.
• Digitally controlled 8-speed shaker with orbital mixing from 575 to 1500 rpm.
• Temperature adjustable from ambient to 40°C with resolution of 0.1°C.
• Digital timer controls shaking or can be operated independently as a timer.
• Outer tinted cover provides further insulation and protection from light.
• NRTL and CE certified
Temperature Range: Ambient to 400C.
Resolution: 0.10CSKU: n/a -
ELISA Analyzer, Medical Equipments
Statfax 3100 Manual Washer
• Fast, clean and precise
• 8-probe manifold
• Push down controlled, pulse dispense
• 1L wash bottle, 1L waste bottle with full level sensor and alarm
• Adjustable dispense volume
• Compact, easy to use and maintain
• Pump generates vacuum & pressure not reliant on gravity or siphon actionSKU: n/a -
Chemistry Analyzers, Medical Equipments, Other Instruments
Statfax 3300 Chemistry Analyzer
• Uses 12 mm round tubes, 1 cm square cuvettes, or built-in flow cell.
• Read cell is temperature-controlled to 37°C.
• Bi-chromatic reading capability 6 filters standard, with spaces for 2 optional filters (340-
o 700nm).
• Flip-up 240 x 128-pixel graphic display shows kinetic plots in real-time.
• Use onboard thermal printer, external printer, or PC.
• Create a work list, run tests, print patient reports. Stores patient data
• Stores control values and creates Levey-Jennings plots for QC.
• IAD filters
• OPTIONAL ACCESSORIES FOR STAT FAX 3300
• Incubates 18 Tubes at 37°C.
• LED at front indicates heating function.
• Temperature displays on 3300 screen.
Tube or cuvette: -0.2 to 2.5 absorbance units
With Flowcell: -0.2 to 3.5 absorbance units
Stability: Drift of no more than 0.005A in 8 hours/bi-
chromaticSKU: n/a -
ELISA Analyzer, Medical Equipments
Statfax 4300 Microplate Reader
PHOTOMETRIC
Optical Measurement Range: -0.20 to 4.0 Absorbance units (A)
Photometric Accuracy: +/-1
Stability: Drift of no more than 0.005A in 8
Light Source: Remote halogen lamp source with lamp saver feature
Wavelengths: Standard: 405, 450, 492, 545, 600, and 630nm
6-filter: 405, 450, 492, 545, 600, and 630nm
Filter options from 405nm to 700nm
Filter type: IAD hardcoat interference, 10nm half bandpass
Vessel: Standard 96-well micro titer plates, or strip trays.ELECTRONIC:
Power Requirements: 115V or 230V AC, 50-60Hz (auto-sensing)
PC Connection: USB Port
Microprocessor: eZ80
Speed: Reads absorbance of 96 wells in about 8 seconds.
Plate Transport: Stepper motor
Certifications: PendingSKU: n/a -
Chemistry Analyzers, Medical Equipments
Statfax 4500
PHOTOMETRIC:
Linear Measurement Range: Tube or cuvette -0.0 to 3.0 Absorbance units (A).
Photometric Accuracy: +/-(1% of the reading + 0.005A)
Stability: Drift of no more than 0.005A in 8 hours/bi-chromatic.
Light Source: Tungsten lamp with lamp saver feature
Standard Wavelengths: 340, 405, 505,545, 580 and 630nm (alternate filters available from 340 to 700nm)
Filter Type: IAD hardcoat interference, 10nm half bandpass
Tube Size: 12 mm round is standard.
Minimum Sample Volume: 1mL for 12mm round tube.SKU: n/a -
ELISA Analyzer, Medical Equipments
Strip Reader Statfax 4700
PHOTOMETRIC
Linear Measurement Range: 0.0 to 3.0 Absorbance units (A).
Photometric Accuracy: +/- (1% of the reading + 0.005A).
Stability: Drift of no more than 0.005A in 8 hours/bichromatic.
Light Source: Tungsten lamp with lamp saver feature.
Standard Wavelengths: Standard: 405, 450, 492, and 630nm.
6-VIS: 405, 450, 492, 545, 600, and 630nm.
6-UV: 340, 405, 450, 492, 545, and 630nm.
(alternate filters available from 340 to 700nm).
Filter Type: IAD hardcoat interference, 10nm half bandpass.
Vessel: Single, double, or break-apart strips up to 12 wells
long.
3-strip loading capacity with 2 options:
R 3×12 carrier for single break-apart or 12 well strips.
R 3×8 carrier for non-break-apart (rigid) or 2×8 strips.SKU: n/a -
Microscope, Other Instruments
Thea-i Fi Microscope with MIPS
Optical System: Semi-Plan achromatic optics with anti-fungal treatment. Uniform centered, Interchangeable & Parfocal, Anti-Fungus treated.
Body: Aluminum die-cast body with all critical movements based on ball bearing & wire guides thereby ensuring smooth & precise manipulation
Mechanical Stage: Co-axial low drive mechanical stage (125mm x 145mm) (+/-5mm) with traverse area of 50mm x76mm (+/-5mm)
Focusing System: Co-axial coarse & fine controls with a focus adjustment and fine adjustment knobs. Coarse Focus range 25mm.
Condenser : Abbe Condenser with aperture iris diaphragm (N.A.
1.25)
focusable with rack pinion through 20mm and a
continuously variable iris diaphragm with a removable
blue filter for daylight observation. Rack & pinion
mounted condenser holder Rack & pinion mounted
condenser holder.
Illumination base (a) Built-in illumination base with pre-centered 6V
with option: 20W halogen light source coupled with an efficient collector lens system Power supply 230V AC. 50Hz (SMPS). Supplied with one spare bulb and spare fuse. Easily replaceable lamp from front.
(b) LED Light source high brightness, longlife
(30,000hrs) 1w LED.
(c) LED light source (with battery back-up) High
brightness, long life (30,000hrs). Battery back-up in-built NiMH Rechargeable batteries provide 6 to 8hrs back-up on full charge.
Nose Piece: Quadruple revolving inward nosepiece based on precision ball-bearing mechanism with positive click stop.SKU: n/a -
Microscope, Other Instruments
Theia-i Microscope
Body: Aluminum die-cast body with all critical movements based on ball bearing & wire guides thereby ensuring smooth & precise manipulation
Mechanical Stage: Co-axial low drive mechanical stage (125mm x 145mm)
(+/-5mm) with traverse area of 50mm x76mm (+/-5mm)
Focusing System: Co-axial coarse & fine controls with a focus adjustment
and fine adjustment knobs.
Coarse Focus Range 28mm (approx.) Fine focus range 0.2mm (approx.)
Condenser holder: Rack & pinion mounted condenser holder
Condenser: Centreable abbe condenser with aperture iris diaphragm
(N.A. 125) focusable with rack & pinion through 20mm and a continuously variable iris diaphragm with a removable blue filter for daylight observation.
Illumination base: (a) Built-in illumination base with pre-centered 6V
20W halogen light source coupled with an efficient collector lens system Power supply 230V AC. 50Hz. single phase
(b) LED Light source high brightness, longlife
(30,000hrs) 1w LED.
(c) LED light source (with battery back-up) High
brightness, long life (30,000hrs) 1w LED. Battery back-up in-built NiMH Rechargeable batteries provide 6 to 8hrs back-up on full charge.
Nose Piece: Quadruple revolving inward nosepiece based on precision ball-bearing mechanism with positive click stop quintuple nosepiece option is also available
Infinity corrected plan Ach: Plan achromatic objectivesSKU: n/a -
-
Medical Equipments, Other Instruments
Uro-dipcheck 240e
SPECIFICATION FOR URO-DIPCHECK 240e
Semi-quantitative reflectance photometer
Measuring using LEDs and a colour detector
Wavelengths: 470,540,650nm
Reading Time: 55s
Speed: Up to 240 tests per hour
Touch Screen (LCD display): 320×240 colour TFT
Built-in thermal printer, 2sec/parameter
External communication to PC/LIS via RS 232 or USB port
Possibility to connect an external keyboard or a bar code reader
Memory capacity: Last 240 measurements
Languages for end-users: EN, DE, ES, FR, IT, RU, PT, CZ
Strips intended for urine analysis with Uro-dipcheck 240e:
Uro-dip 10e
Working Conditions: External power source 7.,5V DC switch adapter 100-
240V/50-60 Hz
Internal power source: battery 6 x 1.5V AA
Power Consumption: 20W max/1W standby
Temperature: Optimum range 15-350C, relative humidity 20-80%
Weight: 0.8kg without adapter, battery and paper roll
Dimensions: 230 x 127 x 110mmSKU: n/a -
Electrolyte Analyzer, Medical Equipments
Z-Lite Pro+ Electrolyte Analyzer
Key Features
• Automatic Sampling, Probe Wiping and Calibration
• Extremely low cost per test
• Intelligent reagent pack with electronic chip
• High precision pump with more durable tuningPrinciple: Direct measurement with ion selective electrode (ISE)
Parameter Conversion: This functionality allows quick change of analyteSample: Whole blood, serum, plasma, CSF and diluted urine, for diluted
(1:5) urine 500 _L
Sample Volume: 130 _L
Measuring Time: 60 seconds
Throughput: 55 samples per 60 minutes
Data Storage: 1 lakh samples, 25000 Urine, 100 QC
Ambient Condition: Temperature: 50C – 400C <85% non-condensing humidity
Output: 128×64 graphics display with Y/N numeric keypad 24 column
thermal printer, USB port
Input Voltage: 100/115-VAC, 50-60 Hz or 220-VAC, 50-60 Hz, 0.75 amp
Size & Weight: 15” W x 12” H x 7.0” D, 6 kg
Battery: 10 hours backup (optional)SKU: n/a