TECHNICAL SPECIFICATION FOR BUCKET CENTRIFUGE
MAX RPM: 4000 RPM, stepless speed adjustment, Pointer show speed
Max RCF: 2325xg
Timer: 0-30min
Rotor capacity: 20mlx12 (standard)
Voltage: 110V 60Hz /220V50Hz
Dimension(mm): 280x310x265mm
Weight: 9kg
Bucket Centrifuge
MAX RPM: 4000 RPM, stepless speed adjustment, Pointer show speed
Max RCF: 2325xg
Timer: 0-30min
Rotor capacity: 20mlx12 (standard)
Voltage: 110V 60Hz /220V50Hz
Dimension(mm): 280x310x265mm
Weight: 9kg
TECHNICAL SPECIFICATION FOR BUCKET CENTRIFUGE
MAX RPM: 4000 RPM, stepless speed adjustment, Pointer show speed
Max RCF: 2325xg
Timer: 0-30min
Rotor capacity: 20mlx12 (standard)
Voltage: 110V 60Hz /220V50Hz
Dimension(mm): 280x310x265mm
Weight: 9kg
Based on 0 reviews
Be the first to review “Bucket Centrifuge” Cancel reply
Related products
-
Blood Gas, Medical Equipments, Other Instruments
Blood Gas Analyzer
0 out of 5(0)Features:
• It is used with the original blood gas analyzer test card (electrochemistry),
• blood gas analyzer reagent pack supporting the use, suitable for the measurement of
• patients in blood pH (PH), carbon dioxide partial pressure (pCO2), oxygen partial
• pressure (pO2 ), sodium ion (Na+), potassium ion (K+), calcium ion (Ca2+), chloride ion
• (Cl–), hematocrit (Hct), Lactic Acid (Lac)* and Glucose (Glu)*.
• The Blood Gas analyzer should only be used by healthcare professionals.
• For in vitro diagnostic use.SKU: n/a -
Chemistry Analyzers, Medical Equipments
Statfax 4500
0 out of 5(0)PHOTOMETRIC:
Linear Measurement Range: Tube or cuvette -0.0 to 3.0 Absorbance units (A).
Photometric Accuracy: +/-(1% of the reading + 0.005A)
Stability: Drift of no more than 0.005A in 8 hours/bi-chromatic.
Light Source: Tungsten lamp with lamp saver feature
Standard Wavelengths: 340, 405, 505,545, 580 and 630nm (alternate filters available from 340 to 700nm)
Filter Type: IAD hardcoat interference, 10nm half bandpass
Tube Size: 12 mm round is standard.
Minimum Sample Volume: 1mL for 12mm round tube.SKU: n/a -
ELISA Analyzer, Medical Equipments
Statfax 4300 Microplate Reader
0 out of 5(0)PHOTOMETRIC
Optical Measurement Range: -0.20 to 4.0 Absorbance units (A)
Photometric Accuracy: +/-1
Stability: Drift of no more than 0.005A in 8
Light Source: Remote halogen lamp source with lamp saver feature
Wavelengths: Standard: 405, 450, 492, 545, 600, and 630nm
6-filter: 405, 450, 492, 545, 600, and 630nm
Filter options from 405nm to 700nm
Filter type: IAD hardcoat interference, 10nm half bandpass
Vessel: Standard 96-well micro titer plates, or strip trays.ELECTRONIC:
Power Requirements: 115V or 230V AC, 50-60Hz (auto-sensing)
PC Connection: USB Port
Microprocessor: eZ80
Speed: Reads absorbance of 96 wells in about 8 seconds.
Plate Transport: Stepper motor
Certifications: PendingSKU: n/a -
Heamatology, Medical Equipments, Other Instruments
Abacus Junior Vet 5
0 out of 5(0)- Sample Volume: 25/50 µl of whole blood in 3/5-part mode
- Measured parameters: 22 parameters, including 5-part WBC differential: WBC, LYM, MON, NEU, EOS, BAS, LYM%,MON%,NEU%,EOS%,BAS%, RBC, HCT, MCV,RDW, HGB, MCH, MCHC, PLT, PCT, MPV, PDW.
- Reagents: Isotonic diluents, lyse, Diff Vet 5, cleaner and rinse
- Throughput: 22-28 tests/hour in 3-part mode
- 15-20 tests/hour in 5-part mode
- Sampling Method: Open tube system with automatic sample rotor
- Sample profiles: -in 5-part mode: Dog, cat, horse, Control blood
- –in 3-part mode: Dog, Cat, Horse, cattle, Pig, Mouse, Rat, Rabbit Ferret, Chimp, Sheep, Goat and user-defined profiles.
- Calibration: Automatic or Manual
- Quality Control: 6 lots
- Software Upgrade: USB
- Data Storage Capacity: 1000 (2000/10000 optional) result, including histograms
- Built-in printer: Seiko “Easy Paper Operation” thermal printer, 56mm wide roll paper (optional)
SKU: n/a
There are no reviews yet.