SPECIFICATION FOR DCEG MACHINE ELECTROCARDIOGRAPH
Number of Channels: 12 Channels
Machine Type : Digital
Lead Selection: Automatic
Frequency : 50Hz
Number of Channels: 12 Channels
Machine Type : Digital
Lead Selection: Automatic
Frequency : 50Hz
SPECIFICATION FOR DCEG MACHINE ELECTROCARDIOGRAPH
Number of Channels: 12 Channels
Machine Type : Digital
Lead Selection: Automatic
Frequency : 50Hz
SPECIFICATION FOR DCEG MACHINE ELECTROCARDIOGRAPH
Number of Channels: 12 Channels
Machine Type : Digital
Lead Selection: Automatic
Frequency : 50Hz
Features:
• It is used with the original blood gas analyzer test card (electrochemistry),
• blood gas analyzer reagent pack supporting the use, suitable for the measurement of
• patients in blood pH (PH), carbon dioxide partial pressure (pCO2), oxygen partial
• pressure (pO2 ), sodium ion (Na+), potassium ion (K+), calcium ion (Ca2+), chloride ion
• (Cl–), hematocrit (Hct), Lactic Acid (Lac)* and Glucose (Glu)*.
• The Blood Gas analyzer should only be used by healthcare professionals.
• For in vitro diagnostic use.
– This instrument can report HBE and HBA2 separately
Methodology: High Performance liquid Chromatography (HPLC)
Test Modes: Standard Mode, variart Mode, Thalassaemia
Test Range: 3%-18%
Precision: CV<15% Test Speed; 130 Secs/T for Variart Mode, 380 Secs/T for Thalassaemia Mode Sample Type: Venous Blood, Firger Peripheral Blood, Lyophilized Whole Blood Peripheral Blood, 500µl (150 Dilution Ratio) Auto Sample 10 Positions Station: Photometer: 415mm+500nm Detector Chromatography Column: Available Tests > 800T
Filter: >400T
Display: 101 “TFT True Colour LCD Touch Screen
Software: Urux software with self- Diagnosis to monitor and detect
system errors
Reagent Kit: Eluent A, Eluent B, Eluent C, Hemolysin, Calibrator, QC
Material ( Weight Sensor ± 1% )
Information input: Scanner or Touch Keypad
Storage: 4000 sample results
TECHNICAL SPECIFICATION FOR INCUBATOR (DNP-9052A)
Model: DNP-9052A
Working size (mm): 350x350x410
Power: 250W
Temperature range: Room temperature+5~65℃
Temperature resolution: 0.1℃
Temperature fluctuation: ±0.5℃
Timer: 0-999min
Voltage: 110V 60Hz /220V 50Hz
Dimension(mm): 470x490x700
Size : 58cm*56cm*80cm / 23in*22.1in*31.5in
Gross Weight : 45kg / 100lb
Net Weight : 34kg / 75lb
• 200 tests per hour
• No carry-over
• Liquid sensing probe tip
• Reflex testing
• Continuous loading
• LIS, STAT
• QC tracking
• Self-monitoring mechanics and optics
• Auto dilute and retest for over-range samples
• Reaction Volume <250uL
• No custom disposables required
• IAD filters
• Automatic service reports
• Standard curve editing
There are no reviews yet.