SPECIFICATION FOR DCEG MACHINE ELECTROCARDIOGRAPH
Number of Channels: 12 Channels
Machine Type : Digital
Lead Selection: Automatic
Frequency : 50Hz
Number of Channels: 12 Channels
Machine Type : Digital
Lead Selection: Automatic
Frequency : 50Hz
SPECIFICATION FOR DCEG MACHINE ELECTROCARDIOGRAPH
Number of Channels: 12 Channels
Machine Type : Digital
Lead Selection: Automatic
Frequency : 50Hz
SPECIFICATION FOR DCEG MACHINE ELECTROCARDIOGRAPH
Number of Channels: 12 Channels
Machine Type : Digital
Lead Selection: Automatic
Frequency : 50Hz
– This instrument can report HBE and HBA2 separately
Methodology: High Performance liquid Chromatography (HPLC)
Test Modes: Standard Mode, variart Mode, Thalassaemia
Test Range: 3%-18%
Precision: CV<15% Test Speed; 130 Secs/T for Variart Mode, 380 Secs/T for Thalassaemia Mode Sample Type: Venous Blood, Firger Peripheral Blood, Lyophilized Whole Blood Peripheral Blood, 500µl (150 Dilution Ratio) Auto Sample 10 Positions Station: Photometer: 415mm+500nm Detector Chromatography Column: Available Tests > 800T
Filter: >400T
Display: 101 “TFT True Colour LCD Touch Screen
Software: Urux software with self- Diagnosis to monitor and detect
system errors
Reagent Kit: Eluent A, Eluent B, Eluent C, Hemolysin, Calibrator, QC
Material ( Weight Sensor ± 1% )
Information input: Scanner or Touch Keypad
Storage: 4000 sample results
Sample material: Capillary, venous or arterial whole blood.
Measurement range: 0-25.6 g/dL (0-256 g/L or 0-15.9 mmol/L).
Results: In about 10 seconds.
Sample volume: 10 µL.
Weight: 500 g (1.10 pounds) with batteries installed.
Power: AC adapter or batteries.
Operating temperature: 10-40 °C (40-104 °F).
Interface: Printer and PC
Quality control: Built-in “selftest”. The system can be verified using liquid controls.
Calibration: The system is factory calibrated against the ICSH reference method for hemoglobin and needs no further calibration.
Accuracy: Correlation of 0.99 when compared to the reference method (ICSH
method).
Key Features
o 4 measuring channels
o Automatic start with standard pipettes
o Increased throughput by additional preparation line
o RFID for security of use
o 7” resistive touch-screen
o Built-in thermal printer
o Printable calibration curves
o Monitoring of expirations of reagent, calibrators and controls
o LIS compatible
Throughput: 86 T/H
Methodology: Electro-chemluminescence Immunoassay (ECLIA)
Test Mode: Standard, STAT
Reagent Channel: 10
Sample Position: 30
Sample Type: Serum, Plasma
Sample Volume: 5-100µl
Reaction Position: 100
Reaction Cups: Disposable
Incubation Temperature: 37+0.50C
Sample Result: 10mins
Calibration: Auto and QC (2 level)
Reagent System: Liquid Level Detection; Refrigeration, 4-150C;
System Reagent: Buffer and Auffer; Slot Temperature 28+20C
Probe: Liquid Level Detection, Probe Crashing Protection, Probe
Blocking Detection
Optional Function: Automatic cap removing
Dimensions: 650mmx620mmx650mm (26.6”Hx24.4” Wx25.5”D)
Weight: 92Kg (203lbs)