SPECIFICATION FOR DCEG MACHINE ELECTROCARDIOGRAPH
Number of Channels: 12 Channels
Machine Type : Digital
Lead Selection: Automatic
Frequency : 50Hz
Number of Channels: 12 Channels
Machine Type : Digital
Lead Selection: Automatic
Frequency : 50Hz
SPECIFICATION FOR DCEG MACHINE ELECTROCARDIOGRAPH
Number of Channels: 12 Channels
Machine Type : Digital
Lead Selection: Automatic
Frequency : 50Hz
SPECIFICATION FOR DCEG MACHINE ELECTROCARDIOGRAPH
Number of Channels: 12 Channels
Machine Type : Digital
Lead Selection: Automatic
Frequency : 50Hz
• Uses 12 mm round tubes, 1 cm square cuvettes, or built-in flow cell.
• Read cell is temperature-controlled to 37°C.
• Bi-chromatic reading capability 6 filters standard, with spaces for 2 optional filters (340-
o 700nm).
• Flip-up 240 x 128-pixel graphic display shows kinetic plots in real-time.
• Use onboard thermal printer, external printer, or PC.
• Create a work list, run tests, print patient reports. Stores patient data
• Stores control values and creates Levey-Jennings plots for QC.
• IAD filters
• OPTIONAL ACCESSORIES FOR STAT FAX 3300
• Incubates 18 Tubes at 37°C.
• LED at front indicates heating function.
• Temperature displays on 3300 screen.
Tube or cuvette: -0.2 to 2.5 absorbance units
With Flowcell: -0.2 to 3.5 absorbance units
Stability: Drift of no more than 0.005A in 8 hours/bi-
chromatic
External Dimensions: 1200mm (w) x 750mm (d) x 1330mm (h)
(2230mm including base stand)
Add 66mm height for outlet filter if fitted
Internal Dimensions: 1107mm (w) x 630mm (d) x 754mm (h)
Base Stand: Optional
Main HEPA Filter: H14 rated at 99.997% efficient to 0.3μm
particulate. Filter seals under negative pressure to prevent leaks into the cabinet.
Outlet HEPA Filter: H14 rated at 99.997% efficient to 0.3μm
particulate. Filter seals under negative pressure to prevent leaks into the cabinet.
Optional 2nd outlet filter available
Air Cleanliness: ISO Class 4
Low Overall Design: Yes
Sliding Sash Yes – Manufactured from Toughened and
Laminated Glass
Internal Lighting: High-intensity adjustable overhead LED lighting
UV Light: Yes – with timer
Electrical Requirements: 220-240V / 50-60Hz AC – 150w (during
Standard operation) 110V / 60Hz also available
Noise Level: circa. 54db(A)
Electrical Socket: 2 electric outlets switched from the main
control system
Net Weight: 170Kg
Construction: Epoxy coated Zintec Mild Steel with
toughened glass glazing panels and removable 3-part stainless steel work surface
Features:
• It is used with the original blood gas analyzer test card (electrochemistry),
• blood gas analyzer reagent pack supporting the use, suitable for the measurement of
• patients in blood pH (PH), carbon dioxide partial pressure (pCO2), oxygen partial
• pressure (pO2 ), sodium ion (Na+), potassium ion (K+), calcium ion (Ca2+), chloride ion
• (Cl–), hematocrit (Hct), Lactic Acid (Lac)* and Glucose (Glu)*.
• The Blood Gas analyzer should only be used by healthcare professionals.
• For in vitro diagnostic use.
TECHNICAL SPECIFICATION FOR INCUBATOR (DNP-9052A)
Model: DNP-9052A
Working size (mm): 350x350x410
Power: 250W
Temperature range: Room temperature+5~65℃
Temperature resolution: 0.1℃
Temperature fluctuation: ±0.5℃
Timer: 0-999min
Voltage: 110V 60Hz /220V 50Hz
Dimension(mm): 470x490x700
Size : 58cm*56cm*80cm / 23in*22.1in*31.5in
Gross Weight : 45kg / 100lb
Net Weight : 34kg / 75lb
There are no reviews yet.