SPECIFICATION FOR DCEG MACHINE ELECTROCARDIOGRAPH
Number of Channels: 12 Channels
Machine Type : Digital
Lead Selection: Automatic
Frequency : 50Hz
Number of Channels: 12 Channels
Machine Type : Digital
Lead Selection: Automatic
Frequency : 50Hz
SPECIFICATION FOR DCEG MACHINE ELECTROCARDIOGRAPH
Number of Channels: 12 Channels
Machine Type : Digital
Lead Selection: Automatic
Frequency : 50Hz
SPECIFICATION FOR DCEG MACHINE ELECTROCARDIOGRAPH
Number of Channels: 12 Channels
Machine Type : Digital
Lead Selection: Automatic
Frequency : 50Hz
Body: Aluminum die-cast body with all critical movements based on ball bearing & wire guides thereby ensuring smooth & precise manipulation
Mechanical Stage: Co-axial low drive mechanical stage (125mm x 145mm)
(+/-5mm) with traverse area of 50mm x76mm (+/-5mm)
Focusing System: Co-axial coarse & fine controls with a focus adjustment
and fine adjustment knobs.
Coarse Focus Range 28mm (approx.) Fine focus range 0.2mm (approx.)
Condenser holder: Rack & pinion mounted condenser holder
Condenser: Centreable abbe condenser with aperture iris diaphragm
(N.A. 125) focusable with rack & pinion through 20mm and a continuously variable iris diaphragm with a removable blue filter for daylight observation.
Illumination base: (a) Built-in illumination base with pre-centered 6V
20W halogen light source coupled with an efficient collector lens system Power supply 230V AC. 50Hz. single phase
(b) LED Light source high brightness, longlife
(30,000hrs) 1w LED.
(c) LED light source (with battery back-up) High
brightness, long life (30,000hrs) 1w LED. Battery back-up in-built NiMH Rechargeable batteries provide 6 to 8hrs back-up on full charge.
Nose Piece: Quadruple revolving inward nosepiece based on precision ball-bearing mechanism with positive click stop quintuple nosepiece option is also available
Infinity corrected plan Ach: Plan achromatic objectives
Samples: Removable rack holds 96 serum vials or 12x75mm tubes, pre-
dilution on-board
Reagents: The standard rack holds 27 various size bottles, optional alternate
racks available
Reaction Plate: Standard 96-well microplates or strip trays – clear for ELISA and opaque white for Chemiluminescent
Linear Range: 0.0 to 3.0A
Filters: long-life IAD
Wavelengths: 340,405,450,505,545,600,630,700 or custom
Sensitivity/Detection Limit: ALP 1×10-21 moles
HRP 1×10-18 moles
Linear range: to 106 RLU
Cross talk: Less than 2.5 x 10-4
Volumes: from 2uL to 1.95 mL with precision better than 2%CV, single and
multi dispense
Probe: detects liquid surface, automatic washing and rinsing
Key Features
o 4 measuring channels
o Automatic start with standard pipettes
o Increased throughput by additional preparation line
o RFID for security of use
o 7” resistive touch-screen
o Built-in thermal printer
o Printable calibration curves
o Monitoring of expirations of reagent, calibrators and controls
o LIS compatible
External Dimensions: 1200mm (w) x 750mm (d) x 1330mm (h)
(2230mm including base stand)
Add 66mm height for outlet filter if fitted
Internal Dimensions: 1107mm (w) x 630mm (d) x 754mm (h)
Base Stand: Optional
Main HEPA Filter: H14 rated at 99.997% efficient to 0.3μm
particulate. Filter seals under negative pressure to prevent leaks into the cabinet.
Outlet HEPA Filter: H14 rated at 99.997% efficient to 0.3μm
particulate. Filter seals under negative pressure to prevent leaks into the cabinet.
Optional 2nd outlet filter available
Air Cleanliness: ISO Class 4
Low Overall Design: Yes
Sliding Sash Yes – Manufactured from Toughened and
Laminated Glass
Internal Lighting: High-intensity adjustable overhead LED lighting
UV Light: Yes – with timer
Electrical Requirements: 220-240V / 50-60Hz AC – 150w (during
Standard operation) 110V / 60Hz also available
Noise Level: circa. 54db(A)
Electrical Socket: 2 electric outlets switched from the main
control system
Net Weight: 170Kg
Construction: Epoxy coated Zintec Mild Steel with
toughened glass glazing panels and removable 3-part stainless steel work surface