Product Carousel Tabs
Abacus 5 Heamatology Analyzer (5 Part Diff)
Throughput: 60 tests/hour
Parameters: a CBC+5 DIFF mode (26 parameters) – 2
histograms: RBC, PLT; 2 scattergrams: 4 diff, WBC, LYM, MON, NEU, EOS, BAS, LYM%, MON%, NEU%, EOS%, BAS%, RBC, HCT, MCV, RDW (sd/cv), HGB, MCH, MCHC,PLT, PCT, MPV, PDW (sd/cv), P-LCC, P-LCR
Laser light: scattering technology for 5-part WBC
differential
Sample volume: 110 μl of whole blood
Closed and open tube sampling, optional autosampler
3 cyanide-free reagents: Diluent, Lyse, Stopper
Data storage capacity: 100,000 records
Operating environment: Temperature: 15–30 °C
Relative humidity: Max 80% (non-condensing)
Multilingual user interface: English, French, Spanish, Croatian, Hungarian,
Italian, Polish, Portuguese, Russian, Turkish, Chinese, German, Greek
Size (Width x Depth x Height): 40 cm x 50 cm x 45 cm, 16” x 20” x 18”
Weight: 35 kg, 77 lbs
Abacus 380 Haematology Analyzer
Abacus Junior Vet 5
eCL8000 eCLIA System
Throughput: 86 T/H
Methodology: Electro-chemluminescence Immunoassay (ECLIA)
Test Mode: Standard, STAT
Reagent Channel: 10
Sample Position: 30
Sample Type: Serum, Plasma
Sample Volume: 5-100µl
Reaction Position: 100
Reaction Cups: Disposable
Incubation Temperature: 37+0.50C
Sample Result: 10mins
Calibration: Auto and QC (2 level)
Reagent System: Liquid Level Detection; Refrigeration, 4-150C;
System Reagent: Buffer and Auffer; Slot Temperature 28+20C
Probe: Liquid Level Detection, Probe Crashing Protection, Probe
Blocking Detection
Optional Function: Automatic cap removing
Dimensions: 650mmx620mmx650mm (26.6”Hx24.4” Wx25.5”D)
Weight: 92Kg (203lbs)
Chemwell Fusion
Samples: Removable rack holds 96 serum vials or 12x75mm tubes, pre-
dilution on-board
Reagents: The standard rack holds 27 various size bottles, optional alternate
racks available
Reaction Plate: Standard 96-well microplates or strip trays – clear for ELISA and opaque white for Chemiluminescent
Linear Range: 0.0 to 3.0A
Filters: long-life IAD
Wavelengths: 340,405,450,505,545,600,630,700 or custom
Sensitivity/Detection Limit: ALP 1×10-21 moles
HRP 1×10-18 moles
Linear range: to 106 RLU
Cross talk: Less than 2.5 x 10-4
Volumes: from 2uL to 1.95 mL with precision better than 2%CV, single and
multi dispense
Probe: detects liquid surface, automatic washing and rinsing
Chemwell 2910 Fully Automated Elisa System
• 200 tests per hour
• No carry-over
• Liquid sensing probe tip
• 8-well wash head
• Level-sensing wash, rinse, and waste bottles
• LIS, STAT
• QC tracking
• Self-monitoring mechanics and optics
• Auto dilute and retest for over-range samples
• Reaction Volume <250uL
• No custom disposables required
• IAD filters
• Creates automatic service reports
• Edit standard curves
Typical throughput: Up to 200 endpoint reactions per hour, up to 170 kinetic
reactions per hour
Dimensions: 36.25″ (92.1cm) left to right, 18.75″ (47.6 cm) height, 21.5″ (54.6 cm) front-to-back
Approximate weight 100 lbs (45kg)
Capabilities: Dilution, pre-dilution, dispensing single or multiple reagents
Probes: 316 stainless steel for maximum reagent compatibility, level sensing
Maximum number of specimens: 96
Maximum number of reagents: Typically 27 to 44 or more (you can program reagents to go in the sample rack; assorted replaceable racks and custom-designed racks are available for various bottle sizes)
Standard reagent rack: 27
Reaction Vessel: Standard microwells, strips or plates
Products Carousel
Heamatology & Chemistry Analyzer
Reagents & Consumables
Trending Products
Bestsellers
Top Categories
Recommendation for you
Your Recently Viewed Products
Statfax 3300 Chemistry Analyzer
• Uses 12 mm round tubes, 1 cm square cuvettes, or built-in flow cell.
• Read cell is temperature-controlled to 37°C.
• Bi-chromatic reading capability 6 filters standard, with spaces for 2 optional filters (340-
o 700nm).
• Flip-up 240 x 128-pixel graphic display shows kinetic plots in real-time.
• Use onboard thermal printer, external printer, or PC.
• Create a work list, run tests, print patient reports. Stores patient data
• Stores control values and creates Levey-Jennings plots for QC.
• IAD filters
• OPTIONAL ACCESSORIES FOR STAT FAX 3300
• Incubates 18 Tubes at 37°C.
• LED at front indicates heating function.
• Temperature displays on 3300 screen.
Tube or cuvette: -0.2 to 2.5 absorbance units
With Flowcell: -0.2 to 3.5 absorbance units
Stability: Drift of no more than 0.005A in 8 hours/bi-
chromatic
Blood Roller Mixer
TECHNICAL SPECIFICATION:
Vibrating: 10-80rpm/min
Rolling: 10-80rpm/min
Vibrating Range: 22mm +/- 1mm
Power Consumption: 12w
Voltage: AC220V±10% (50/60Hz)
Net Weight: 3.6kg
Volume: 394x266x98
Fuse: 2A
Working Shift: continuously
Packing Quantity: 2 sets/package
Packing Measurement: 49*36*42
PRECAUTIONS
Put the machine on a flat table.
Machine should have a good earth.
Blood Gas Analyzer
Features:
• It is used with the original blood gas analyzer test card (electrochemistry),
• blood gas analyzer reagent pack supporting the use, suitable for the measurement of
• patients in blood pH (PH), carbon dioxide partial pressure (pCO2), oxygen partial
• pressure (pO2 ), sodium ion (Na+), potassium ion (K+), calcium ion (Ca2+), chloride ion
• (Cl–), hematocrit (Hct), Lactic Acid (Lac)* and Glucose (Glu)*.
• The Blood Gas analyzer should only be used by healthcare professionals.
• For in vitro diagnostic use.
Abacus 5 Heamatology Analyzer (5 Part Diff)
Throughput: 60 tests/hour
Parameters: a CBC+5 DIFF mode (26 parameters) – 2
histograms: RBC, PLT; 2 scattergrams: 4 diff, WBC, LYM, MON, NEU, EOS, BAS, LYM%, MON%, NEU%, EOS%, BAS%, RBC, HCT, MCV, RDW (sd/cv), HGB, MCH, MCHC,PLT, PCT, MPV, PDW (sd/cv), P-LCC, P-LCR
Laser light: scattering technology for 5-part WBC
differential
Sample volume: 110 μl of whole blood
Closed and open tube sampling, optional autosampler
3 cyanide-free reagents: Diluent, Lyse, Stopper
Data storage capacity: 100,000 records
Operating environment: Temperature: 15–30 °C
Relative humidity: Max 80% (non-condensing)
Multilingual user interface: English, French, Spanish, Croatian, Hungarian,
Italian, Polish, Portuguese, Russian, Turkish, Chinese, German, Greek
Size (Width x Depth x Height): 40 cm x 50 cm x 45 cm, 16” x 20” x 18”
Weight: 35 kg, 77 lbs
Abacus 380 Haematology Analyzer
Thea-i Fi Microscope with MIPS
Optical System: Semi-Plan achromatic optics with anti-fungal treatment. Uniform centered, Interchangeable & Parfocal, Anti-Fungus treated.
Body: Aluminum die-cast body with all critical movements based on ball bearing & wire guides thereby ensuring smooth & precise manipulation
Mechanical Stage: Co-axial low drive mechanical stage (125mm x 145mm) (+/-5mm) with traverse area of 50mm x76mm (+/-5mm)
Focusing System: Co-axial coarse & fine controls with a focus adjustment and fine adjustment knobs. Coarse Focus range 25mm.
Condenser : Abbe Condenser with aperture iris diaphragm (N.A.
1.25)
focusable with rack pinion through 20mm and a
continuously variable iris diaphragm with a removable
blue filter for daylight observation. Rack & pinion
mounted condenser holder Rack & pinion mounted
condenser holder.
Illumination base (a) Built-in illumination base with pre-centered 6V
with option: 20W halogen light source coupled with an efficient collector lens system Power supply 230V AC. 50Hz (SMPS). Supplied with one spare bulb and spare fuse. Easily replaceable lamp from front.
(b) LED Light source high brightness, longlife
(30,000hrs) 1w LED.
(c) LED light source (with battery back-up) High
brightness, long life (30,000hrs). Battery back-up in-built NiMH Rechargeable batteries provide 6 to 8hrs back-up on full charge.
Nose Piece: Quadruple revolving inward nosepiece based on precision ball-bearing mechanism with positive click stop.
Chem 5V3 Chemistry Analyzer
Unique Features of Chem 5V3:
• 150 Open Programmable Test Memory
• 10 Assay Modes including Absorbance, Linear & Non-Linear Calculations for 1 Point, Rate A & 1 Point sample blank methods
• Dual Cuvette Facility
• Low Volume Flowcell for low reagent/Test
• Extensive Q.C. Program and Memory facility
• Universal Power Adaptor for ease of us
No of Test Parameters: 150, Open user programmable
Assay Modes: 10
Measurement Modes: Monochromatic/Bi-chromatic
Flowcell Temperature: 25” C, 30o C, 37o C, by Peltier control
Type of Cuvettes: Dual Cuvette (Flow cell and Polystyrene manual cuvette)
Flow cell volume: 18 ul/33ul (optional)
Aspiration volume: 300-999 ul (user programmable) using peristaltic pump
Wavelengths: 340,405,505,546,578,630nm
Display: 240 x 64 Graphic LCD display
Printer: External and Internal
Interface port: RS 232 c Serial interface & Centronics parallel port for external printer.
Micro Plate Reader Stat Fax 4200
UNIQUE FEATURES
• User-programmable open system.
• User-programmable plate formatting.
• Fully automatic reading.
• Reads 96 wells in about 12 seconds.
• Built-in thermal printer with graphics capability.
• Interactive touch-screen LCD with USB mouse option.
• Bi-chromatic optics.
• Standard model includes four filters.
• Six-filter models are available.
• IAD filters
SPECIFICATIONS
PHOTOMETRIC
Linear Measurement Range: 0.0 to 4.0 Absorbance Units (A)
Photometric Accuracy: +/-1%
Stability: Drift of no more than 0.005A in 8 hours
Light Source: Remote halogen lamp source with lamp saver feature.
Wavelengths: Standard: 405, 450, 492, 545, 600, and 630nm
6-filter: 405, 450, 492, 545, 600, and 630nm
Filter options from 405nm to 700nm
Filter type: IAD hardcoat interference, 10nm half bandpass
Vessel: Standard 96-well micro-titer plates, or strip trays.
ELECTRONIC
Display: Interactive 5.7” (14.5cm) graphical touch-screen LCD
Printer: Thermal dot matrix, 20 character per line, plus graphics.
Power Requirements: 115V or 230V AC, 50-60Hz (auto-sensing)
Interface: USB mouse
Speed: Read absorbance of 96 wells in about 10 seconds.
Plate Transport: Stepper motor
Chemwell 2902 Fully Automated Chemistry Analyzer
Chemwell 2902 Fully Automated Chemistry Analyzer
• 200 tests per hour
• No carry-over
• Liquid sensing probe tip
• Reflex testing
• Continuous loading
• LIS, STAT
• QC tracking
• Self-monitoring mechanics and optics
• Auto dilute and retest for over-range samples
• Reaction Volume <250uL
• No custom disposables required
• IAD filters
• Automatic service reports
• Standard curve editing