Product Carousel Tabs
Abacus 5 Heamatology Analyzer (5 Part Diff)
Throughput: 60 tests/hour
Parameters: a CBC+5 DIFF mode (26 parameters) – 2
histograms: RBC, PLT; 2 scattergrams: 4 diff, WBC, LYM, MON, NEU, EOS, BAS, LYM%, MON%, NEU%, EOS%, BAS%, RBC, HCT, MCV, RDW (sd/cv), HGB, MCH, MCHC,PLT, PCT, MPV, PDW (sd/cv), P-LCC, P-LCR
Laser light: scattering technology for 5-part WBC
differential
Sample volume: 110 μl of whole blood
Closed and open tube sampling, optional autosampler
3 cyanide-free reagents: Diluent, Lyse, Stopper
Data storage capacity: 100,000 records
Operating environment: Temperature: 15–30 °C
Relative humidity: Max 80% (non-condensing)
Multilingual user interface: English, French, Spanish, Croatian, Hungarian,
Italian, Polish, Portuguese, Russian, Turkish, Chinese, German, Greek
Size (Width x Depth x Height): 40 cm x 50 cm x 45 cm, 16” x 20” x 18”
Weight: 35 kg, 77 lbs
Abacus 380 Haematology Analyzer
Abacus Junior Vet 5
eCL8000 eCLIA System
Throughput: 86 T/H
Methodology: Electro-chemluminescence Immunoassay (ECLIA)
Test Mode: Standard, STAT
Reagent Channel: 10
Sample Position: 30
Sample Type: Serum, Plasma
Sample Volume: 5-100µl
Reaction Position: 100
Reaction Cups: Disposable
Incubation Temperature: 37+0.50C
Sample Result: 10mins
Calibration: Auto and QC (2 level)
Reagent System: Liquid Level Detection; Refrigeration, 4-150C;
System Reagent: Buffer and Auffer; Slot Temperature 28+20C
Probe: Liquid Level Detection, Probe Crashing Protection, Probe
Blocking Detection
Optional Function: Automatic cap removing
Dimensions: 650mmx620mmx650mm (26.6”Hx24.4” Wx25.5”D)
Weight: 92Kg (203lbs)
Chemwell Fusion
Samples: Removable rack holds 96 serum vials or 12x75mm tubes, pre-
dilution on-board
Reagents: The standard rack holds 27 various size bottles, optional alternate
racks available
Reaction Plate: Standard 96-well microplates or strip trays – clear for ELISA and opaque white for Chemiluminescent
Linear Range: 0.0 to 3.0A
Filters: long-life IAD
Wavelengths: 340,405,450,505,545,600,630,700 or custom
Sensitivity/Detection Limit: ALP 1×10-21 moles
HRP 1×10-18 moles
Linear range: to 106 RLU
Cross talk: Less than 2.5 x 10-4
Volumes: from 2uL to 1.95 mL with precision better than 2%CV, single and
multi dispense
Probe: detects liquid surface, automatic washing and rinsing
Chemwell 2910 Fully Automated Elisa System
• 200 tests per hour
• No carry-over
• Liquid sensing probe tip
• 8-well wash head
• Level-sensing wash, rinse, and waste bottles
• LIS, STAT
• QC tracking
• Self-monitoring mechanics and optics
• Auto dilute and retest for over-range samples
• Reaction Volume <250uL
• No custom disposables required
• IAD filters
• Creates automatic service reports
• Edit standard curves
Typical throughput: Up to 200 endpoint reactions per hour, up to 170 kinetic
reactions per hour
Dimensions: 36.25″ (92.1cm) left to right, 18.75″ (47.6 cm) height, 21.5″ (54.6 cm) front-to-back
Approximate weight 100 lbs (45kg)
Capabilities: Dilution, pre-dilution, dispensing single or multiple reagents
Probes: 316 stainless steel for maximum reagent compatibility, level sensing
Maximum number of specimens: 96
Maximum number of reagents: Typically 27 to 44 or more (you can program reagents to go in the sample rack; assorted replaceable racks and custom-designed racks are available for various bottle sizes)
Standard reagent rack: 27
Reaction Vessel: Standard microwells, strips or plates
Products Carousel
Heamatology & Chemistry Analyzer
Reagents & Consumables
Trending Products
Bestsellers
Top Categories
Recommendation for you
Your Recently Viewed Products
H8 HbA1C HPLC Analyzer (Β-Thalassaemia)
H8 HbA1C HPLC Analyzer (Β-Thalassaemia)
– This instrument can report HBE and HBA2 separately
Methodology: High Performance liquid Chromatography (HPLC)
Test Modes: Standard Mode, variart Mode, Thalassaemia
Test Range: 3%-18%
Precision: CV<15% Test Speed; 130 Secs/T for Variart Mode, 380 Secs/T for Thalassaemia Mode Sample Type: Venous Blood, Firger Peripheral Blood, Lyophilized Whole Blood Peripheral Blood, 500µl (150 Dilution Ratio) Auto Sample 10 Positions Station: Photometer: 415mm+500nm Detector Chromatography Column: Available Tests > 800T
Filter: >400T
Display: 101 “TFT True Colour LCD Touch Screen
Software: Urux software with self- Diagnosis to monitor and detect
system errors
Reagent Kit: Eluent A, Eluent B, Eluent C, Hemolysin, Calibrator, QC
Material ( Weight Sensor ± 1% )
Information input: Scanner or Touch Keypad
Storage: 4000 sample results
Manual Vacuum Aspirator
Sterile
Available in 8 sizes
Two opposing apertures (4-8mm)
Large, single scoop aperture (9,10,12mm)
Color-coded by size for easy differentiation and identification (adapter kit required for the flexible Karman Cannula)
Printed insertion guides
Used for uterine aspiration in conjunction with the IPAS MVA Plus Aspirator and the Double Valve Aspirator (adapter kit required for the Flexible Karman Cannula) Sizes 4mm, 5mm and 6mm of the flexible Karman Cannula can also be used for uterine aspiration with the single valve aspiration. No adapters are required.
Semi-rigid: The tactile response of a rigid curette with the gentle probe of a flexible cannula
Utilizes permanently-integrated bases
Eliminates the need for adapters to connect to the aspirator
Constructed with “wings” to facilitate easy insertion and removal from the aspirator
Length: Approx. 24cm or 9.5in
Made of medical grade, latex free, polypropylene plastic.
Z-Lite Pro+ Electrolyte Analyzer
Key Features
• Automatic Sampling, Probe Wiping and Calibration
• Extremely low cost per test
• Intelligent reagent pack with electronic chip
• High precision pump with more durable tuning
Principle: Direct measurement with ion selective electrode (ISE)
Parameter Conversion: This functionality allows quick change of analyte
Sample: Whole blood, serum, plasma, CSF and diluted urine, for diluted
(1:5) urine 500 _L
Sample Volume: 130 _L
Measuring Time: 60 seconds
Throughput: 55 samples per 60 minutes
Data Storage: 1 lakh samples, 25000 Urine, 100 QC
Ambient Condition: Temperature: 50C – 400C <85% non-condensing humidity
Output: 128×64 graphics display with Y/N numeric keypad 24 column
thermal printer, USB port
Input Voltage: 100/115-VAC, 50-60 Hz or 220-VAC, 50-60 Hz, 0.75 amp
Size & Weight: 15” W x 12” H x 7.0” D, 6 kg
Battery: 10 hours backup (optional)
Statfax 4300 Microplate Reader
PHOTOMETRIC
Optical Measurement Range: -0.20 to 4.0 Absorbance units (A)
Photometric Accuracy: +/-1
Stability: Drift of no more than 0.005A in 8
Light Source: Remote halogen lamp source with lamp saver feature
Wavelengths: Standard: 405, 450, 492, 545, 600, and 630nm
6-filter: 405, 450, 492, 545, 600, and 630nm
Filter options from 405nm to 700nm
Filter type: IAD hardcoat interference, 10nm half bandpass
Vessel: Standard 96-well micro titer plates, or strip trays.
ELECTRONIC:
Power Requirements: 115V or 230V AC, 50-60Hz (auto-sensing)
PC Connection: USB Port
Microprocessor: eZ80
Speed: Reads absorbance of 96 wells in about 8 seconds.
Plate Transport: Stepper motor
Certifications: Pending
Abacus Junior Vet 5
Micro Plate Reader Stat Fax 4200
UNIQUE FEATURES
• User-programmable open system.
• User-programmable plate formatting.
• Fully automatic reading.
• Reads 96 wells in about 12 seconds.
• Built-in thermal printer with graphics capability.
• Interactive touch-screen LCD with USB mouse option.
• Bi-chromatic optics.
• Standard model includes four filters.
• Six-filter models are available.
• IAD filters
SPECIFICATIONS
PHOTOMETRIC
Linear Measurement Range: 0.0 to 4.0 Absorbance Units (A)
Photometric Accuracy: +/-1%
Stability: Drift of no more than 0.005A in 8 hours
Light Source: Remote halogen lamp source with lamp saver feature.
Wavelengths: Standard: 405, 450, 492, 545, 600, and 630nm
6-filter: 405, 450, 492, 545, 600, and 630nm
Filter options from 405nm to 700nm
Filter type: IAD hardcoat interference, 10nm half bandpass
Vessel: Standard 96-well micro-titer plates, or strip trays.
ELECTRONIC
Display: Interactive 5.7” (14.5cm) graphical touch-screen LCD
Printer: Thermal dot matrix, 20 character per line, plus graphics.
Power Requirements: 115V or 230V AC, 50-60Hz (auto-sensing)
Interface: USB mouse
Speed: Read absorbance of 96 wells in about 10 seconds.
Plate Transport: Stepper motor
B-Medical MT 110 Transport Box
Cooling: Active (Compressor)
Gross Volume: 106L
External Dimension (HxWxD): 555x790x500mm
Net weight (empty): 33kg
Application Range: +50C to 320C ambient temperature
Box material: Polyethylene
Insulation: Polyurethane
Operating Temperature: +40C or 220C
Voltage AC: 100-240 V
Voltage DC: 12/24 V
Power Consumption: 65W app