Product Carousel Tabs
Abacus 5 Heamatology Analyzer (5 Part Diff)
Throughput: 60 tests/hour
Parameters: a CBC+5 DIFF mode (26 parameters) – 2
histograms: RBC, PLT; 2 scattergrams: 4 diff, WBC, LYM, MON, NEU, EOS, BAS, LYM%, MON%, NEU%, EOS%, BAS%, RBC, HCT, MCV, RDW (sd/cv), HGB, MCH, MCHC,PLT, PCT, MPV, PDW (sd/cv), P-LCC, P-LCR
Laser light: scattering technology for 5-part WBC
differential
Sample volume: 110 μl of whole blood
Closed and open tube sampling, optional autosampler
3 cyanide-free reagents: Diluent, Lyse, Stopper
Data storage capacity: 100,000 records
Operating environment: Temperature: 15–30 °C
Relative humidity: Max 80% (non-condensing)
Multilingual user interface: English, French, Spanish, Croatian, Hungarian,
Italian, Polish, Portuguese, Russian, Turkish, Chinese, German, Greek
Size (Width x Depth x Height): 40 cm x 50 cm x 45 cm, 16” x 20” x 18”
Weight: 35 kg, 77 lbs
Abacus 380 Haematology Analyzer
Abacus Junior Vet 5
eCL8000 eCLIA System
Throughput: 86 T/H
Methodology: Electro-chemluminescence Immunoassay (ECLIA)
Test Mode: Standard, STAT
Reagent Channel: 10
Sample Position: 30
Sample Type: Serum, Plasma
Sample Volume: 5-100µl
Reaction Position: 100
Reaction Cups: Disposable
Incubation Temperature: 37+0.50C
Sample Result: 10mins
Calibration: Auto and QC (2 level)
Reagent System: Liquid Level Detection; Refrigeration, 4-150C;
System Reagent: Buffer and Auffer; Slot Temperature 28+20C
Probe: Liquid Level Detection, Probe Crashing Protection, Probe
Blocking Detection
Optional Function: Automatic cap removing
Dimensions: 650mmx620mmx650mm (26.6”Hx24.4” Wx25.5”D)
Weight: 92Kg (203lbs)
Chemwell Fusion
Samples: Removable rack holds 96 serum vials or 12x75mm tubes, pre-
dilution on-board
Reagents: The standard rack holds 27 various size bottles, optional alternate
racks available
Reaction Plate: Standard 96-well microplates or strip trays – clear for ELISA and opaque white for Chemiluminescent
Linear Range: 0.0 to 3.0A
Filters: long-life IAD
Wavelengths: 340,405,450,505,545,600,630,700 or custom
Sensitivity/Detection Limit: ALP 1×10-21 moles
HRP 1×10-18 moles
Linear range: to 106 RLU
Cross talk: Less than 2.5 x 10-4
Volumes: from 2uL to 1.95 mL with precision better than 2%CV, single and
multi dispense
Probe: detects liquid surface, automatic washing and rinsing
Chemwell 2910 Fully Automated Elisa System
• 200 tests per hour
• No carry-over
• Liquid sensing probe tip
• 8-well wash head
• Level-sensing wash, rinse, and waste bottles
• LIS, STAT
• QC tracking
• Self-monitoring mechanics and optics
• Auto dilute and retest for over-range samples
• Reaction Volume <250uL
• No custom disposables required
• IAD filters
• Creates automatic service reports
• Edit standard curves
Typical throughput: Up to 200 endpoint reactions per hour, up to 170 kinetic
reactions per hour
Dimensions: 36.25″ (92.1cm) left to right, 18.75″ (47.6 cm) height, 21.5″ (54.6 cm) front-to-back
Approximate weight 100 lbs (45kg)
Capabilities: Dilution, pre-dilution, dispensing single or multiple reagents
Probes: 316 stainless steel for maximum reagent compatibility, level sensing
Maximum number of specimens: 96
Maximum number of reagents: Typically 27 to 44 or more (you can program reagents to go in the sample rack; assorted replaceable racks and custom-designed racks are available for various bottle sizes)
Standard reagent rack: 27
Reaction Vessel: Standard microwells, strips or plates
Products Carousel
Heamatology & Chemistry Analyzer
Reagents & Consumables
Trending Products
Bestsellers
Top Categories
Recommendation for you
Your Recently Viewed Products
Manual Vacuum Aspirator
Sterile
Available in 8 sizes
Two opposing apertures (4-8mm)
Large, single scoop aperture (9,10,12mm)
Color-coded by size for easy differentiation and identification (adapter kit required for the flexible Karman Cannula)
Printed insertion guides
Used for uterine aspiration in conjunction with the IPAS MVA Plus Aspirator and the Double Valve Aspirator (adapter kit required for the Flexible Karman Cannula) Sizes 4mm, 5mm and 6mm of the flexible Karman Cannula can also be used for uterine aspiration with the single valve aspiration. No adapters are required.
Semi-rigid: The tactile response of a rigid curette with the gentle probe of a flexible cannula
Utilizes permanently-integrated bases
Eliminates the need for adapters to connect to the aspirator
Constructed with “wings” to facilitate easy insertion and removal from the aspirator
Length: Approx. 24cm or 9.5in
Made of medical grade, latex free, polypropylene plastic.
Abacus 380 Haematology Analyzer
Chemwell Fusion
Samples: Removable rack holds 96 serum vials or 12x75mm tubes, pre-
dilution on-board
Reagents: The standard rack holds 27 various size bottles, optional alternate
racks available
Reaction Plate: Standard 96-well microplates or strip trays – clear for ELISA and opaque white for Chemiluminescent
Linear Range: 0.0 to 3.0A
Filters: long-life IAD
Wavelengths: 340,405,450,505,545,600,630,700 or custom
Sensitivity/Detection Limit: ALP 1×10-21 moles
HRP 1×10-18 moles
Linear range: to 106 RLU
Cross talk: Less than 2.5 x 10-4
Volumes: from 2uL to 1.95 mL with precision better than 2%CV, single and
multi dispense
Probe: detects liquid surface, automatic washing and rinsing
Chemwell 2910 Fully Automated Elisa System
• 200 tests per hour
• No carry-over
• Liquid sensing probe tip
• 8-well wash head
• Level-sensing wash, rinse, and waste bottles
• LIS, STAT
• QC tracking
• Self-monitoring mechanics and optics
• Auto dilute and retest for over-range samples
• Reaction Volume <250uL
• No custom disposables required
• IAD filters
• Creates automatic service reports
• Edit standard curves
Typical throughput: Up to 200 endpoint reactions per hour, up to 170 kinetic
reactions per hour
Dimensions: 36.25″ (92.1cm) left to right, 18.75″ (47.6 cm) height, 21.5″ (54.6 cm) front-to-back
Approximate weight 100 lbs (45kg)
Capabilities: Dilution, pre-dilution, dispensing single or multiple reagents
Probes: 316 stainless steel for maximum reagent compatibility, level sensing
Maximum number of specimens: 96
Maximum number of reagents: Typically 27 to 44 or more (you can program reagents to go in the sample rack; assorted replaceable racks and custom-designed racks are available for various bottle sizes)
Standard reagent rack: 27
Reaction Vessel: Standard microwells, strips or plates
Z-Lite Pro+ Electrolyte Analyzer
Key Features
• Automatic Sampling, Probe Wiping and Calibration
• Extremely low cost per test
• Intelligent reagent pack with electronic chip
• High precision pump with more durable tuning
Principle: Direct measurement with ion selective electrode (ISE)
Parameter Conversion: This functionality allows quick change of analyte
Sample: Whole blood, serum, plasma, CSF and diluted urine, for diluted
(1:5) urine 500 _L
Sample Volume: 130 _L
Measuring Time: 60 seconds
Throughput: 55 samples per 60 minutes
Data Storage: 1 lakh samples, 25000 Urine, 100 QC
Ambient Condition: Temperature: 50C – 400C <85% non-condensing humidity
Output: 128×64 graphics display with Y/N numeric keypad 24 column
thermal printer, USB port
Input Voltage: 100/115-VAC, 50-60 Hz or 220-VAC, 50-60 Hz, 0.75 amp
Size & Weight: 15” W x 12” H x 7.0” D, 6 kg
Battery: 10 hours backup (optional)
B-Medical MT 110 Transport Box
Cooling: Active (Compressor)
Gross Volume: 106L
External Dimension (HxWxD): 555x790x500mm
Net weight (empty): 33kg
Application Range: +50C to 320C ambient temperature
Box material: Polyethylene
Insulation: Polyurethane
Operating Temperature: +40C or 220C
Voltage AC: 100-240 V
Voltage DC: 12/24 V
Power Consumption: 65W app
I8-M700 Medical Waste Incinerator
MEDICAL WASTE INCINERATOR I8-M700-1
Combustion Chamber Volume (m3): 6.75m3
Mental thickness: 4mm
Burn Rate: up to 300kg per hour
Oprational Temperature: >850°C
Gas Rention: 2 Secs
Fuel Consumption: 40 – 50 ltrs per hour
Average Ash Residue (%): 3%
Thermostatic Device: Yes
Shippin weight (Kg): 15000kg
Dimensions (l, w, h): 6.04m x 1.91m x 5.75m
Door Size(m): 4.58m x 1.50m
Parameter Limits Measured
Total dust 30 mg/m3 12 mg/m3
Sulphur dioxide 200 mg/m3 2,4 mg/m3
Nitrogen dioxide 400 mg/m3 60 mg/m3
Carbon monoxide 100 mg/m3 78,3 mg/m
ERBA XL-200 Fully Automated Chemistry Analyzer with ISE
Throughput: 200 photometric tests per hour and 400 tests per hour with ISE* (Optional ISE with Na, K+, Cl-, Li+)
System Type: Discrete, Open Automated, Random Access, Patient Prioritized Clinical Chemistry Analyzer
Onboard Parameters: upto 50 + 4 ISE
Sample Type: Serum, Plasma, Urine, CSF, HbA1c using Whole Blood
Programmable Parameters: Unlimited
Analytical Methods: 1-Point, 2-Point, Rate-A, Rate-B, Direct Potentiometry
Calibration: Linear, Non-Linear, Multipoint
Photometer: Static Photometer
Absorbance Range: 0-3.0 Absorbance
Light Source: Halogen Lamp 12V/20 W
Optics: 8 Filters (340-700nm) 340, 405, 505,546,578,600,660,700nm
Director: B Silicon photo diodes
Sample Unit: 39 positions for samples/blank/calibrator/control & STAT sample.
H8 HbA1C HPLC Analyzer (Β-Thalassaemia)
H8 HbA1C HPLC Analyzer (Β-Thalassaemia)
– This instrument can report HBE and HBA2 separately
Methodology: High Performance liquid Chromatography (HPLC)
Test Modes: Standard Mode, variart Mode, Thalassaemia
Test Range: 3%-18%
Precision: CV<15% Test Speed; 130 Secs/T for Variart Mode, 380 Secs/T for Thalassaemia Mode Sample Type: Venous Blood, Firger Peripheral Blood, Lyophilized Whole Blood Peripheral Blood, 500µl (150 Dilution Ratio) Auto Sample 10 Positions Station: Photometer: 415mm+500nm Detector Chromatography Column: Available Tests > 800T
Filter: >400T
Display: 101 “TFT True Colour LCD Touch Screen
Software: Urux software with self- Diagnosis to monitor and detect
system errors
Reagent Kit: Eluent A, Eluent B, Eluent C, Hemolysin, Calibrator, QC
Material ( Weight Sensor ± 1% )
Information input: Scanner or Touch Keypad
Storage: 4000 sample results
Abacus Junior Vet 5
Thea-i Fi Microscope with MIPS
Optical System: Semi-Plan achromatic optics with anti-fungal treatment. Uniform centered, Interchangeable & Parfocal, Anti-Fungus treated.
Body: Aluminum die-cast body with all critical movements based on ball bearing & wire guides thereby ensuring smooth & precise manipulation
Mechanical Stage: Co-axial low drive mechanical stage (125mm x 145mm) (+/-5mm) with traverse area of 50mm x76mm (+/-5mm)
Focusing System: Co-axial coarse & fine controls with a focus adjustment and fine adjustment knobs. Coarse Focus range 25mm.
Condenser : Abbe Condenser with aperture iris diaphragm (N.A.
1.25)
focusable with rack pinion through 20mm and a
continuously variable iris diaphragm with a removable
blue filter for daylight observation. Rack & pinion
mounted condenser holder Rack & pinion mounted
condenser holder.
Illumination base (a) Built-in illumination base with pre-centered 6V
with option: 20W halogen light source coupled with an efficient collector lens system Power supply 230V AC. 50Hz (SMPS). Supplied with one spare bulb and spare fuse. Easily replaceable lamp from front.
(b) LED Light source high brightness, longlife
(30,000hrs) 1w LED.
(c) LED light source (with battery back-up) High
brightness, long life (30,000hrs). Battery back-up in-built NiMH Rechargeable batteries provide 6 to 8hrs back-up on full charge.
Nose Piece: Quadruple revolving inward nosepiece based on precision ball-bearing mechanism with positive click stop.
Statfax 4500
PHOTOMETRIC:
Linear Measurement Range: Tube or cuvette -0.0 to 3.0 Absorbance units (A).
Photometric Accuracy: +/-(1% of the reading + 0.005A)
Stability: Drift of no more than 0.005A in 8 hours/bi-chromatic.
Light Source: Tungsten lamp with lamp saver feature
Standard Wavelengths: 340, 405, 505,545, 580 and 630nm (alternate filters available from 340 to 700nm)
Filter Type: IAD hardcoat interference, 10nm half bandpass
Tube Size: 12 mm round is standard.
Minimum Sample Volume: 1mL for 12mm round tube.
Neo-Bil Plus
SPECIFICATION
Measure unit: 5/30 mg/dl or 85/510 µmol/l
Measure System: Photometric
Sample Reading: On a single-point of the capillary
Zero and checkings: Completely automated
Interferential: Automatically compensated
Reading Time: 3s approx. even on highly haemolized samples
Reading inaccuracy: <5%
Detector: Silicon photodiode
Optical Filters: 455 and 575nm
Programming: By membrane keypad
Results: On LCD and printer
Keypad: 17 buttons
Display: 2 lines with 16 columns
Printer: 20 columns with thermal paper
Data Storage: Last 100 results
Interface: SB Port
Complimentary Items
ACL-LP-0500 - Lancettes
ACL-PL-747500 - Sealing Plasticine
ACL-CP-74931 - Glass Capillaries (75mm)
CRT-01-058 - Thermal Paper